نتایج جستجو برای: distal interlocking screw

تعداد نتایج: 88021  

Journal: :Journal of orthopaedic surgery 2012
Sunil Govind Kulkarni Ankit Varshneya Govind Shivram Kulkarni Milind Govind Kulkarni Vidisha Sunil Kulkarni Ruta Milind Kulkarni

PURPOSE To assess outcomes of antegrade interlocking nailing for supracondylar or intercondylar fractures of the distal femur. METHODS Records of 10 women and 20 men aged 20 to 70 (mean, 48.7) years who underwent antegrade interlocking nailing for distal femoral fractures were reviewed. 23 patients had closed fractures and 7 had open fractures; 6 had associated fractures of the forearm or tib...

2011

INTRODUCTION: Long bone diaphyseal fractures are a very common injury encountered in orthopedic practice. This type of fracture is often treated using an intramedullary (IM) nail. In this day and age there are many options in regards to the orientation of the distal interlocking screws. The goal of this study was to determine if the distance between two distal locking screws affects the stabili...

Journal: :Nepal Medical College journal : NMCJ 2008
S K Giri B R Adhikari G B Gurung Dr Rc A R Bajracharya K Khatri

Intramedullary interlocking tibial nailing is usually performed using an image intensifier. But being expensive, it is not available in the most of the hospitals of resource-poor countries of the world. The purpose of this study is to analyze the results of interlocking nailing without the use of an image intensifier. This is the retrospective study of 55 diaphyseal tibial fractures treated wit...

2012

In this study Interlocking nails were used in order to fixate the canine femoral fractures and to examine the effects of the implants on fracture healing, clinically and radipgraphically in 19 dogs. The material of the study consisted 19 dogs of medium-large size, which were brought to Ankara University, Faculty of Veterinary Medicine, Department of Orthopedics and Traumatology because of injur...

2015
Wasudeo Gadegone Yogesh Salphale Vijayanand Lokhande

A study was performed in adults to determine the efficacy of closed reduction and intramedullary nailing in dynamic mode on union, implant failure and incidence of malalignment in patients who sustained an extra-articular fracture of the distal tibia. Methods: Between January 2007 and December 2013, one hundred and twelve patients of distal tibia that involved the distal 6 cm of the tibia were ...

Journal: :The Cochrane database of systematic reviews 2012
Xin Duan Mohammed Al-Qwbani Yan Zeng Wei Zhang Zhou Xiang

BACKGROUND Intramedullary nailing is commonly used for treating fractures of the tibial shaft. These fractures are one of the most common long bone fractures in adults. OBJECTIVES To assess the effects (benefits and harms) of different methods and types of intramedullary nailing for treating tibial shaft fractures in adults. SEARCH METHODS We searched the Cochrane Bone, Joint and Muscle Tra...

Journal: :Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca 2008
S Kuhn M Hansen P M Rommens

Numerous modifications in nail and screw design have led to the development of the Expert Tibial Nail. It enables the surgeon to further extend the spectrum of fractures eligible for intramedullary nailing. In the proximal metaphysis spongious bone screws achieve an optimized purchase in the cancellous bone. Multidirectional interlocking screws ensure that alignment can be well maintained and s...

Journal: :JNGMC 2023

Introduction: Distal tibia fracture tends to angulate while using a standard intramedullary interlocking nail. By single Poller screw, the medullary cavity's functional diameter is reduced. This leads angulation correction and three-point fixations, which improve mechanical stability of nail-bone construct.
 Aims: To assess radiological results nail poller screw in management adult distal ...

Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...

Journal: :archives of trauma research 0
sascha rausch trauma department, jena university hospital, jena, germany; trauma department, jena university hospital, jena, germany. tel: +49-36419322889, fax: +49-36419322802 ivan marintschev trauma department, jena university hospital, jena, germany isabel graul trauma department, jena university hospital, jena, germany arne wilharm trauma department, jena university hospital, jena, germany kajetan klos foot and ankle department, catholic medical center, mainz, germany gunther o. hofmann trauma department, jena university hospital, jena, germany; berufsgenossenschaftliche kliniken bergmannstrost halle, halle, germany

conclusions we recommend the additional 2d-fluoroscopic tangential view for detection of screw misplacements caused by overlength, with penetration on the dorsal cortical surface of the distal radius, predominantly observed for the most lateral screw position. the use of intraoperative 3d fluoroscopy did not become accepted in our clinical routine, due to the technical demanding and time consum...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید