نتایج جستجو برای: cp ti

تعداد نتایج: 69146  

2017
Ming Zhu Rui Wang Chen Chen Haibin Zhang Guojun Zhang

As a newly developed conductive ceramic with wide application prospects, the electrochemical corrosion behavior of Ti3SiC2 in 3.5% NaCl solution was investigated by potentiodynamic polarization, potentiostatic polarization and electrochemical impedance spectroscopy. Commercially pure titanium (CP Ti) was selected for comparative, and cooperated with XRD, XPS, SEM, the passivation behavior, corr...

Journal: :International Journal of Nanomedicine 2006
Saba Choudhary Mikal Berhe Karen M Haberstroh Thomas J Webster

In the body, vascular cells continuously interact with tissues that possess nanostructured surface features due to the presence of proteins (such as collagen and elastin) embedded in the vascular wall. Despite this fact, vascular stents intended to restore blood flow do not have nanoscale surface features but rather are smooth at the nanoscale. As the first step towards creating the next genera...

Journal: :Langmuir : the ACS journal of surfaces and colloids 2008
Isabel Van De Keere Ronnie Willaert Annick Hubin Jean Vereecken

The surface of a biomaterial interacts with the body fluid upon implantation in the human body. The biocompatibility of a material is strongly influenced by the adsorption of proteins onto the surface. Titanium is frequently used as a biomaterial for implants in orthopedics and cardiovascular devices. Understanding the biocompatibility is very important to improve implants. The surface chemistr...

Journal: :Journal of materials science. Materials in medicine 2010
Yan Liu Jing Mao Bin Zhou Wei Wei Shiqiang Gong

Commercially pure titanium (cp-Ti) is widely used in the field of long-term clinical oral implantology owing to its ability to allow close bone-implant apposition. The optimization of its function based on artificial proteins has become a key issue in the development of improved cp-Ti implants. Here, we set out to identify peptide aptamers with preferential adsorption towards titanium-based imp...

Journal: :Nature materials 2013
Wanbiao Hu Yun Liu Ray L Withers Terry J Frankcombe Lasse Norén Amanda Snashall Melanie Kitchin Paul Smith Bill Gong Hua Chen Jason Schiemer Frank Brink Jennifer Wong-Leung

The immense potential of colossal permittivity (CP) materials for use in modern microelectronics as well as for high-energy-density storage applications has propelled much recent research and development. Despite the discovery of several new classes of CP materials, the development of such materials with the required high performance is still a highly challenging task. Here, we propose a new el...

2014
Mi-Kyung Han Moon-Jin Hwang Dae-Hee Won Yang-Soo Kim Ho-Jun Song Yeong-Joon Park

In order to investigate the relationship between phase/microstructure and various properties of Ti-xAg alloys, a series of Ti-xAg alloys with Ag contents ranging from 5 to 20 wt% were prepared. The microstructures were characterized using X-ray diffractometry (XRD), optical microscopy (OM), scanning electron microscopy (SEM) and transmission electron microscopy (TEM). All of the Ti-xAg alloys s...

Journal: :Organic letters 2003
Alejandro F Barrero Antonio Rosales Juan M Cuerva J Enrique Oltra

[reaction: see text] A general procedure for the synthesis of both 12,6- and 12,8-eudesmanolides has been developed. The key step is the titanocene-catalyzed radical cyclization of accessible epoxygermacrolides. The novel reagent 2,4,6-trimethyl-1-trimethylsilylpyridinium chloride, both compatible with oxiranes and capable of regenerating Cp(2)TiCl(2) from Cp(2)Ti(Cl)H and Cp(2)Ti(Cl)OAc, playe...

Journal: :Brazilian oral research 2005
Wagner Sotero Fragoso Guilherme Elias Pessanha Henriques Edwin Fernando Ruiz Contreras Marcelo Ferraz Mesquita

Commercially pure titanium (CP Ti) has been widely applied to fabricate cast devices because of its favorable properties. However, the mold temperature recommended for the manufacture of casts has been considered relatively low, causing inadequate castability and poor marginal fit of cast crowns. This study evaluated and compared the influence of mold temperature (430 degrees C--as control, 550...

Journal: :Brazilian dental journal 2008
Renata Cristina Silveira Rodrigues Ana Paula Macedo Erica Miranda de Torres Maria da Glória Chiarello de Mattos Ricardo Faria Ribeiro

The objective of this study was to evaluate the retention force of T-bar clasps made from commercially pure titanium (CP Ti) and cobalt-chromium (Co-Cr) alloy by the insertion/removal test simulating 5 years use. Thirty-six frameworks were cast from CP Ti (n=18) and Co-Cr alloy (n=18) with identical prefabricated patterns on refractory casts from a distal extension mandibular hemi-arch segment....

2012
Bo-Ah Lee Choong-Hee Kang Mong-Sook Vang Young-Suk Jung Xing Hui Piao Ok-Su Kim Hyun-Ju Chung Young-Joon Kim

PURPOSE The aim of the present study was to evaluate the biological response of alkali- and heat-treated titanium-8tantalum-3niobium surfaces by cell proliferation and alkaline phosphatase (ALP) activity analysis. METHODS Commercial pure titanium (group cp-Ti) and alkali- and heat-treated titanium-8tantalum-3niobium (group AHT) disks were prepared. The surface properties were evaluated using ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید