نتایج جستجو برای: coriolis mass flow meter

تعداد نتایج: 954173  

2009
Timothy J. Cunningham

Structural Integrity Meter Verification is a robust new Coriolis verification technology which uses the onboard electronics to very accurately measure the stiffness of the flowtubes. The flow tube stiffness is directly related to the flow calibration factor and is uninfluenced by process conditions. Meter Verification compares the measured stiffness to the factory baseline stiffness to confirm ...

Coriolis mass flow meters are one of the most accurate tools to measure the mass flow in the industry. However, two-phase mode (gas-liquid) may cause severe operating difficulties as well as decreasing certitude in measurement. This paper presents a method based on fuzzy systems to correct the error and improve the reliability of these sensors in the presence of two-phase model fluid. Definite ...

Journal: :International Journal of Metrology and Quality Engineering 2012

Journal: :IOP Conference Series: Materials Science and Engineering 2022

Abstract The performance of many cryocoolers that utilize the Joule-Thomson effect can be improved by using a gas-mixture as working fluid. This paper presents measurement setup to characterize sorption compressor operating with binary mixture. composition mixture delivered is determined in-flow correlating outputs Coriolis flow meter and thermal mass-flow meter. Based on this method, was measu...

2015
D. Alveringh J. Groenesteijn K. Ma

We report on a novel capacitive detection principle for Coriolis mass flow sensors which allows for one order of magnitude increased sensitivity. The detection principle consists of two pairs of comb-structures: one pair produces two signals with a phase shift directly dependent on the mass flow, the other pair is used to cancel the actuation signal. This results in larger phase shifts for the ...

2016
D. Alveringh J. Groenesteijn J. C. Lötters

We report on a novel capacitive detection principle for Coriolis mass flow sensors which allows for three times increased sensitivity. Capacitive Coriolis mass flow sensors are normally read out by two electrodes that measure the ratio between the actuation mode and the Coriolis mode, which is induced by the mass flow. This ratio results in a phase shift between the two electrodes. By adding tw...

2015
Chris Mills

It is also common for flowmeters to be installed downstream of a two or three phase separator. If the well conditions change or the separator has been incorrectly sized, then it is possible that the oil liquid outlet may have some gas carry under. The effects of gas entrainment on the output of ultrasonic and Coriolis meters has been reported previously [1] [2]. It is already known that gas ent...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید