نتایج جستجو برای: cascade refrigeration cycle
تعداد نتایج: 320163 فیلتر نتایج به سال:
Using absorption refrigeration cycles instead of vapor compression refrigeration cycles can drastically decrease energy consumption. In these systems, high level of energy consumption is reduced due to the partially elimination of vapor compression refrigeration systems. On the other hand, utilization of waste heat of the plant, which is a very good opportunity for energy saving, is possible. ...
in this paper, a new combined power and refrigeration cycle is proposed, which combines the rankin power cycle and the ejector refrigeration cycle. this combined cycle produces both power output and refrigeration output simultaneously. this cycle is driven by the flue gas of gas turbines, industrial waste heats, solar energy and geothermal energy. an exergy analysis is performed to guide the th...
Capacity and efficiency of any refrigerating system diminish rapidly as the difference between the evaporating and condensing temperature is increased by reduction in the evaporator temperature. The single stage vapour compression refrigeration system is limited to an evaporator temperature of -40 C. Below temperature of -40 C the either cascade refrigeration system or multi stage vapour compre...
Capacity and efficiency of any refrigerating system diminish rapidly as the difference between the evaporating and condensing temperature is increased by a reduction in the evaporator temperature. The single stage vapour compression refrigeration system using various refrigerants are limited to an evaporator temperature of -40 0C. Below temperature of -40 0C the either cascade refrigeration sys...
The present work deals with thermodynamic analysis of cascade refrigeration system using ozone friendly refrigerants pair R507A and R23. R507A is azeotropic mixture composed of HFC refrigerants R125/R143a (50%/50% wt.). R23 is a single component HFC refrigerant used as replacement to CFC refrigerant R13 in low temperature applications. These refrigerants have zero ozone depletion potential and ...
abstract: minimizing the work consumed in refrigeration system is the most effective measure to reduce the cost of products in sub-ambient chemical processes. the introduction of mixed working fluids into refrigeration system in place of pure working fluids is a recent advancement applied in the field. due to the lack of systematic design method for mixed refrigerant cycle (mrc), conventional a...
In an attempt to improve the performance of hybrid absorption and mechanical vapor compression refrigeration systems and to determine the fundamental reasons for such improvements, two configurations of the hybrid refrigeration cycle with a booster compressor at different positions of the cycle (between the evaporation and the absorber, or between the generator and the condenser) are simulated ...
Usually, it is common to use the internal heat exchanger subcooler-superheater after the condenser and before the expansion valve in the compression refrigeration cycles. In this study, the effect of the heat exchanger is evaluated by using recovery heat exchanger after the compressor and before the condenser. To this end, the vapor compression refrigeration cycle with conventional heat exchang...