Nadège Anizan Hao Wang Xian C Zhou Robert F Hobbs Richard L Wahl Eric C Frey

BACKGROUND Absolute quantitative single-photon emission computed tomography (SPECT) has several important applications including monitoring tumor response after treatment and dose estimation for targeted radionuclide therapy treatment planning. Obtaining quantitative SPECT images in absolute activity units requires the use of a calibration factor, and the repeatability of this directly affects ...

2014
Bin Fang Wusheng Chou Li Ding

An optimal calibration method for a microelectro-mechanical inertial measurement unit (MIMU) is presented in this paper. The accuracy of the MIMU is highly dependent on calibration to remove the deterministic errors of systematic errors, which also contain random errors. The overlapping Allan variance is applied to characterize the types of random error terms in the measurements. The calibratio...

2012
B. Meurers

After a 12 years’ observation in Vienna (VI), the superconducting gravimeter GWR C025 has been transferred in autumn 2007 to the new Conrad observatory (CO) 60 km SW of Vienna. It is one of few instruments which were operated at different stations. This aspect motivated a re-analysis of all calibration experiments performed so far in VI and CO, focused on the direct impact of drift effects and ...

2015
N. Geetha Sravani Vinay Kumar Nilagiri Shrikant R. Bharadwaj

Eccentric infrared photorefraction is an attractive tool for measuring refractive errors of young children and uncooperative subjects, for it allows quick and non-invasive acquisition of data from both eyes simultaneously over a reasonably large dioptric range. Accuracy of refraction in this technique depends on calibration of luminance slope formed across the pupil into diopters (defocus calib...

Journal: :journal of biomedical physics and engineering 0
s j hosseinialiabadi s m hosseini pooya h afarideh f mianji

normal 0 false false false en-us x-none fa background: the angular dependency of response for tld cards may cause deviation  from its true value on the results of environmental dosimetry, since tlds may  be exposed to radiation at different angles of incidence from the surrounding area. objective: a 3d setting of tld cards has been calibrated isotropically in a standard  radiation field to eval...

Journal: :iranian journal of medical physics 0

introduction cr-39 detectors are widely used for radon and progeny measurement in the air. in this paper, using the monte carlo simulation, the possibility of using the cr-39 for direct measurement of radon and progeny in water is investigated. materials and methods assuming the random position and angle of alpha particle emitted by radon and progeny, alpha energy and angular spectrum that arri...

Journal: :Applied optics 2011
Demetrius D Venable David N Whiteman Monique N Calhoun Afusat O Dirisu Rasheen M Connell Eduardo Landulfo

We have investigated a technique that allows for the independent determination of the water vapor mixing ratio calibration factor for a Raman lidar system. This technique utilizes a procedure whereby a light source of known spectral characteristics is scanned across the aperture of the lidar system's telescope and the overall optical efficiency of the system is determined. Direct analysis of th...

2002
Kip Bishofberger

After initial checks, I noticed egregious differences between the apparatus as I found it and earlier literature. A thorough investigation then ensued to establish a new calibration factor (and to uncover when the calibration factor changed). The rest of this document details these measurements, but the final conclusion of this work is to find that the beam momentum relates to the spectrometer ...

Journal: :Journal of Physics: Conference Series 2021