نتایج جستجو برای: biological phantom
تعداد نتایج: 480117 فیلتر نتایج به سال:
introduction: in diagnostic and therapeutic procedures, dosimetric studies are performed on the dosimetric systems in order to comply the radiation safety standards. monte carlo methods are used due to the high complexity and cost of patient-specific phantom construction. the high complexity of the digitized phantoms greatly increases the time and computational task of the monte carlo calculati...
Microdosimetric single event spectra as a function of depth in a phantom for the 290 MeV/nucleon therapeutic carbon beam at HIMAC were measured by using a tissue equivalent proportional counter (TEPC). Two types of geometries were used: one is a fragment particle identification measurement (PID-mode) with time of flight (TOF) method without a backward phantom, and the other is an in-phantom mea...
We have proposed a new frequency difference method using a weighted voltage difference (WFD-EIT) between two frequencies [1, 2]. Previous studies demonstrated its feasibility through numerical experiments and two-dimensional phantom experiments. In this study, we validate the WFD-EIT algorithm on a three-dimensional hemisphere phantom using a multi-frequency EIT system KHU Mark1. We built the h...
introduction: in this study, we intend to use diffuse optical tomography (dot) as a noninvasive, safe and low cost technique that can be considered as a functional imaging method and mention the importance of image reconstruction in accuracy and procession of image. one of the most important and fastest methods in image reconstruction is the boundary element method (bem). this method is introdu...
A new method of Monte Carlo simulation has been developed to simulate the spatial distribution of photon density of converging laser beams propagating in a turbid medium such as the phantom of biological tissue. This method can be used to obtain steady-state light distribution in the tissue phantom for a continuous-wave laser beam. We have calculated the steady-state distribution of the photon ...
Introduction: In vitro dosimetric verification prior to patient treatment plays a key role in accurate and precision radiotherapy treatment delivery. Since the human body is a heterogeneous medium, the aim of this study was to design a heterogeneous pelvic phantom for radiotherapy quality assurance. Material and Methods: A pelvic phantom was ...
This study evaluated the effective dose of Ga-67 for a patient undergoing Ga-67 citrate nuclear examination by applying thermoluminescent dosimeter (TLD) technique and an indigenous water phantom. The Ga-67 radionuclide remaining in the body inevitably generated a measurable internal dose even though gamma camera scanning took only minutes to complete the clinical examination. For effective sim...
High-molecular gel containing capsulate thermo-chromic liquid crystal is made to visualize three-dimensional distribution of electromagnetic power absorption. A preliminary experiment is performed at frequency of 1.5GHz. As a result of the experiment, the three-dimensional distribution of electromagnetic power absorption is clearly visualized. The result shows that the gel can be used as a phan...
PURPOSE Research and development of various accelerator-based irradiation systems for boron neutron capture therapy (BNCT) is underway throughout the world. Many of these systems are nearing or have started clinical trials. Before the start of treatment with BNCT, the relative biological effectiveness (RBE) for the fast neutrons (over 10 keV) incident to the irradiation field must be estimated....
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید