نتایج جستجو برای: asymmetrical windings

تعداد نتایج: 10317  

Journal: :IEEE Access 2021

This paper reveals the fundamental reason for asymmetrical issue in magnetic-geared machines (MGMs) based on flux modulation theory. The analysis indicates that magnetic circuits of three-phase windings MGMs are inherently asymmetrical. is even more severe conventional consequent-pole (CP-MGMs) because distorted field. Hence, to address issue, a novel structure featuring enhanced harmonic elimi...

2016
Mohsen Rahimi Mostafa Parniani

This paper proposes a competent and effective scheme to enhance the ride-through capability of DFIGbased wind turbines under unbalanced voltage dip conditions. The proposed method is realized through joint use of the rotor-side converter control and a three-phase stator damping resistor (SDR) placed in series with the stator windings. By means of an asymmetrical SDR idea, during the unbalanced ...

Journal: :Eastern-European Journal of Enterprise Technologies 2021

The paper presents studies of the system "induction generator-induction motor" with parametric asymmetry on a mathematical model to determine quality generated electricity in load operating modes. A has been developed taking into account losses steel and asymmetry. analysis transient characteristics an induction generator when motor is connected symmetrical asymmetrical modes operation carried ...

Journal: :Energies 2023

The doubly salient electromagnetic generator (DSEG) has the advantages of flexible control, high robustness, and low cost. Since multiple stator poles share a common set field windings, magnetic circuit each phase is asymmetrical, which limits output performance DSEG. three-phase current balance control for DSEG system was proposed. By investigating waveform under angular position (APC), predic...

2005
Hideki Honda Akira Asakawa Shigeru Yokoyama

When steep lightning surge enters a pole-mounted distribution transformer, the voltage distribution of the internal windings is unbalanced. It is known that a layer-to-layer short or a turn-to-turn short occurs where the voltage distribution of windings is high. In this paper, the voltage distribution of the windings was measured at the primary and secondary sides of the transformer using a tes...

2014
Jianning Yin Mingxing Tian Guohan Yin

There is the magnetic coupling among control windings of controllable reactor of transformer type (CRT), the decoupling integrated magnetic technology is applied to the structure design of CRT in this paper. To realize the decoupling among the control windings we propose a magnetic integrated structure of CRT by providing low magnetic resistance magnetic circuit for control windings magnetic fl...

2014
Yanjun Yu Huangqiu Zhu Si Zeng

In order to decouple traditional levitation windings and armature windings, a new selfdecoupling magnetic levitation generator (SDMLG) is proposed for wind turbines. This new generator adopts double-stator structure. The armature windings are in the outer stator, and the levitation windings are in the inner stator. The rotor is made of a distributed hollow structure, so that it can effectively ...

2008
Juraj KURIMSKÝ Iraida KOLCUNOVÁ Roman CIMBALA

High voltage insulation is loosing its quality during the operation of high voltage machines and generators. Degrading high voltage stator insulation is the main reason for sudden breakdown of stator windings. Partial discharge measurements can reveal a lot of defects in stator windings of high voltage rotating machines with operating voltage more than 3,3kV. Partial discharge monitoring provid...

Journal: :نشریه دانشکده فنی 0
حسین محسنی فرامرز رهبر

usually both ends of a transformer winding are at the same side of the magnetic core. with this arrangement there are automaticaly the same number of the turns for each winding in both core windows next to the middle leg of a three phase three leg core type transformer. contrary to this arrangement it is possible to put the two ends of a winding at the different sides of the core. in this case ...

This paper presents a new single to three phase converter using rotating magnetic field transformer. Conventional transformers have been used in many converters aiming at supplementary improvements and they usually have no critical effect on the conversion technique. In this paper, the conversion technique is based on a special rotating magnetic field transformer in which there are two windings...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید