نتایج جستجو برای: air detector

تعداد نتایج: 262577  

2015
R. Hiller

Tunka-Rex is a new radio detector for extensive air showers from cosmic rays, built in 2012 as an extension to Tunka133. The latter is a non-imaging air-Cherenkov detector, located near Lake Baikal, Siberia. With its 25 radio antennas, Tunka-Rex extends over an area of 1 km2 with a spacing of 200 m and therefore is expected to be sensitive to an primary energy range of approximately 1017-1018 e...

2010
T. Palani Selvam Biju Keshavkumar

Relative absorbed-dose energy response correction R for different detector materials in water, PMMA and polystyrene phantoms are calculated using Monte Carlo-based EGSnrc code system for ¹²⁵I and ¹⁶⁹Yb brachytherapy sources. The values of R obtained for ¹²⁵I source are 1.41, 0.92, 3.97, 0.47, 8.32 and 1.10, respectively, for detector materials LiF, Li₂B₄O₇ , A1₂O₃, diamond, silicon diode and ai...

Journal: :iranian journal of toxicology 0
آتنا رفیعی پور athena rafieepour arak university of medical sciences فرشید قربانی شهنا farshid ghorbani shahna hamedan university of medical sciences زهرا هاشمی zahra hashemi ahvaz university of medical sciences فرهاد قمری farhad ghamari arak university of medical sciences

background: nanotechnology is a new approach that has been lionized in recent years. one of its applications is its consumption as an absorbent. in this study, the single-wall carbon nanotubes (swcnts) were used as an absorbent for sampling benzene in the air. materials and methods: for this study, swcnts manufactured by iran and skc’s activated charcoal were used for sampling benzene vapors. p...

2011
R. Schnell K. - Th. Brinkmann H. - G. Zaunick

The PANDA Experiment at FAIR will include a MicroVertex-Detector (MVD) for tracking and vertexing. The MVD will be composed of silicon pixel detectors and double-sided silicon strip detectors. The strip part will contain approximately 200,000 channels that need to be read out with highly integrated front-ends. A specific feature of the PANDA detector is the data acquisition concept [1]. Contrar...

Journal: :The Analyst 2015
T F Limero E G Nazarov M Menlyadiev G A Eiceman

The air quality monitor (AQM), which included a portable gas chromatograph (GC) and a detector was interfaced to a mass spectrometer (MS) by introducing flow from the GC detector to the atmospheric pressure ion source of the MS. This small GC system, with a gas recirculation loop for carrier and detector make-up gases, comprised an inlet to preconcentrate volatile organic compounds (VOCs) in ai...

2005
Thomas Schwetz Walter Winter

We propose that reactor experiments could be used to constrain the environment dependence of neutrino mass and mixing parameters, which could be induced due to an acceleron coupling to matter fields. There are several short-baseline reactor experiment projects with different fractions of air and earth matter along the neutrino path. Moreover, the short baselines, in principle, allow the physica...

Journal: :Dental materials journal 2006
Haruka Yokota Shisei Kubo Hiroaki Yokota Masahiro Ohsawa Yoshihiko Hayashi

This study investigated the effect of a caries-detecting solution on the tensile bond strength (TBS) to sound bovine dentin--which was either rinsed thoroughly of or contaminated with the caries-detecting solution. Caries Detector (1.0% acid red in propylene glycol) was applied on flat dentin surfaces for 10 seconds, rinsed, and dried with syringe air. In another group, Caries Detector was not ...

Journal: :Industrial health 2003
Michiyo Azuma Yoko Endo Takeji Miyazaki Yoko Hikita Hiroki Ikeda Yoshihumi Moriya Ichiro Hara Shunichi Araki

In order to determine the efficacy of a detector tube method in formaldehyde (HCHO) measurement, we performed a chamber experiment and a field study. The experiment clearly showed that the value obtained by the detector tube method was significantly correlated to that obtained using an active-DNPH method, and was not influenced by the coexistence of toluene, xylene or carbon monoxide, but was b...

2000
G. B. Yodh

Milagrito, a large, covered water-Cherenkov detector, was the world's "rst air-shower-particle detector sensitive to cosmic gamma rays below 1 TeV. It served as a prototype for the Milagro detector and operated from February 1997 to May 1998. This paper gives a description of Milagrito, a summary of the operating experience, and early results that demonstrate the capabilities of this technique....

2004
G. Sciocchetti G. Cotellessa E. Soldano M. Pagliari

A new instrument was developed to measure radon exposure with the use of passive monitors like nuclear track etch detectors. It is based on a device to be switched on and off to permit accurate measurements of timed exposures. The detector arrangement consists of a small cylindrical chamber, a mobile piston inside, a filter holder, a detector holder. The internal sampling volume is variable. Th...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید