نتایج جستجو برای: 6mv photons
تعداد نتایج: 47464 فیلتر نتایج به سال:
PURPOSE To evaluate the clinical outcome of early glottic cancer (GC) treated by primary radiotherapy (RT) with 6 MV photons. METHODS AND MATERIALS We retrospectively reviewed the medical records of 695 consecutive patients with T1N0 and T2N0 GC treated between 1983 and 2005 by RT in our institution. Clinical outcome in terms of local control (LC), overall survival (OS) and cause- specific su...
The use of Monte Carlo methods in photon beam treatment planning is becoming feasible due to advances in hardware and algorithms. However, a major challenge is the modeling of the radiation produced by individual linear accelerators. Monte Carlo simulation through the accelerator head or a parameterized source model may be used for this purpose. In this work, the latter approach was chosen due ...
PURPOSE As stereotactic treatment modalities grow towards becoming the standard of care, the need for accurate dose computation in small fields is becoming increasingly essential. The purpose of this study is to evaluate the response of different detectors, intended for small field dosimetry, in jaw defined small rectangular fields by analyzing output factors from a stereotactic clinical accele...
Purpose: To study the benefits of Directional Bremsstrahlung Splitting (DBS) dose variance reduction technique in BEAMnrc Monte Carlo (MC) code for Oncor® linac at 6MV and 18MV energies. Materials and Method: A MC model of Oncor® linac was built using BEAMnrc MC Code and verified by the measured data for 6MV and 18MV energies of various field sizes. Then Oncor® machine was modele...
This work investigates the accuracy of skin dose calculations using the Eclipse treatment planning system. Skin dose was measured using micro-MOSFETs for a range of irradiation conditions (open fields, physical wedges, dynamic wedges, different SSDs) for 6MV and 10MV beams, and compared with the mean dose calculated to a 2mm thick "skin" structure for semi-cylindrical phantoms (representative o...
As regards, the selection of appropriate energy in radiotherapy tumors that are placed in non-homogen areas is important, so the aim of the present study is evaluating the effect of 6 and 15MV photon beam energies on dose distribution in 3D-CRT for lower esophageal and rectal cancers. 12 patients with lower esophageal cancer and 12 patients with rectal cancer respectively, with the prescription...
BACKGROUND AND PURPOSE The purpose of this study was to quantify dose distribution errors by comparing actual dose measurements with the calculated values done by the software. To evaluate the outcome of radiation overexposure related to Panama's accident and in response to ensure that the treatment planning systems (T.P.S.) are being operated in accordance with the appropriate quality assuranc...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید