نتایج جستجو برای: 43u1 protocol

تعداد نتایج: 250051  

Journal: :Medical physics 2012
Jose Perez-Calatayud Facundo Ballester Rupak K Das Larry A Dewerd Geoffrey S Ibbott Ali S Meigooni Zoubir Ouhib Mark J Rivard Ron S Sloboda Jeffrey F Williamson

PURPOSE Recommendations of the American Association of Physicists in Medicine (AAPM) and the European Society for Radiotherapy and Oncology (ESTRO) on dose calculations for high-energy (average energy higher than 50 keV) photon-emitting brachytherapy sources are presented, including the physical characteristics of specific (192)Ir, (137)Cs, and (60)Co source models. METHODS This report has be...

Hossein Tavakoli-Anbaran, Ome Leila Ahmadi

 Introduction:The commercial 252Cf sources are too large in size and clinical applications of neutronbrachytherapy (NBT) are limited to a small number of intracavitary treatments of cervical cancers. Recently, under the Cooperative Research and Development Agreement (CRADA) with Isotron Inc., the Oak Ridge National Laboratory (ORNL) encapsulated a new medical 252Cf sources, cal...

Journal: :Medical physics 2004
Mark J Rivard Bert M Coursey Larry A DeWerd William F Hanson M Saiful Huq Geoffrey S Ibbott Michael G Mitch Ravinder Nath Jeffrey F Williamson

Since publication of the American Association of Physicists in Medicine (AAPM) Task Group No. 43 Report in 1995 (TG-43), both the utilization of permanent source implantation and the number of low-energy interstitial brachytherapy source models commercially available have dramatically increased. In addition, the National Institute of Standards and Technology has introduced a new primary standar...

2012
Mohammad Taghi Bahreyni Toossi Mahdi Ghorbani Ali Asghar Mowlavi Ali Soleimani Meigooni

BACKGROUND Dosimetric characteristics of a high dose rate (HDR) GZP6 Co-60 brachytherapy source have been evaluated following American Association of Physicists in MedicineTask Group 43U1 (AAPM TG-43U1) recommendations for their clinical applications. MATERIALS AND METHODS MCNP-4C and MCNPX Monte Carlo codes were utilized to calculate dose rate constant, two dimensional (2D) dose distribution...

2013
Sedigheh Sina Reza Faghihi Ali Soleimani Meigooni Zahra Siavashpour Mohammad Amin Mosleh-Shirazi

BACKGROUND The old Treatment Planning Systems (TPSs) used for intracavitary brachytherapy with Cs-137 Selectron source utilize traditional dose calculation methods, considering each source as a point source. Using such methods introduces significant errors in dose estimation. As of 1995, TG-43 is used as the main dose calculation formalism in treatment TPSs. OBJECTIVES The purpose of this stu...

2013
Islam Mohammad Anwarul Mir Md. Akramuzzaman Golam Abu Zakaria

PURPOSE The purpose of this study is to obtain the dosimetric parameters of the new BEBIG (60)Co brachytherapy source following by TG-43U1 recommendation with appropriate electron cutoff energy (0.521 MeV). MATERIAL AND METHODS The new BEBIG (60)Co brachytherapy source is used to calculate the TG-43U1 parameters. EGSnrc-based Monte Carlo simulation code has been used to calculate the radial d...

Introduction: 103Pd is a low energy source, which is used in brachytherapy. According to the standards of American Association of Physicists in Medicine, dosimetric parameters determination of brachytherapy sources before the clinical application was considered significantly important. Therfore, the present study aimed to compare the dosimetric parameters of the target source using the water ph...

Journal: :iranian journal of radiation research 0
m. zehtabian radiation research center and radiation medicine department, school of engineering, shiraz university, shiraz, iran r. faghihi radiation research center and radiation medicine department, school of engineering, shiraz university, shiraz, iran s. sina radiation research center and radiation medicine department, school of engineering, shiraz university, shiraz, iran

background: iodine brachytherapy sources with low photon energies have been widely used in treating cancerous tumors. dosimetric parameters of brachytherapy sources should be determined according to aapm tg-43u1 recommendations before clinical use. monte carlo codes are reliable tools in calculation of these parameters for brachytherapy sources. materials and methods: dosimetric parameters (dos...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید