نتایج جستجو برای: 113 omron

تعداد نتایج: 17844  

Journal: :Blood pressure monitoring 2003
Mohamed A El Assaad Jirar A Topouchian Roland G Asmar

BACKGROUND Two devices for self-measurement of blood pressure at the brachial artery-the Omron M5-I and the Omron 705IT-were evaluated according to the international protocol of the European Society of Hypertension. DESIGN The international validation protocol is divided into two phases: the first phase is performed on 15 selected subjects and if the device passes this phase, 18 supplementary...

Journal: :American journal of hypertension 2011
Feng-Hua Ding Wang-Xiang Fan Rui-Yan Zhang Qi Zhang Yan Li Ji-Guang Wang

BACKGROUND To investigate the accuracy of the SphygmoCor and Omron HEM9000-AI devices in the estimation of central blood pressure (BP) in comparison with the simultaneous invasive catheter measurement. METHODS The radial arterial pulse was sequentially recorded by the use of the Omron and SphygmoCor devices in 33 patients, with the calibration of the brachial oscillometric BP, to derive centr...

2014
Jirar Topouchian Davide Agnoletti Jacques Blacher¹ Ahmed Youssef Mirna N Chahine Isabel Ibanez Nathalie Assemani Roland Asmar

BACKGROUND Four oscillometric devices, including the Omron M6 Comfort, Omron HEM-7420, Withings BP-800, and Polygreen KP-7670, designed for self-blood pressure measurement (SBPM) were evaluated according to the European Society of Hypertension (ESH) International Protocol Revision 2010 in four separate studies. METHODS The four devices measure brachial blood pressure (BP) using the oscillomet...

2018
Mirna N Chahine Jirar Topouchian Parounak Zelveian Zoya Hakobyan Arevik Melkonyan Alaa Azaki Reem Diab Aya Harb Roland Asmar

Background Following the European Society of Hypertension International Protocol (ESH-IP) Revision 2010, QardioArm® and Omron M6 Comfort IT® oscillometric devices were evaluated in the general population and in patients with type II diabetes, respectively, for self-blood pressure (BP) measurement. Methods Both devices, QardioArm® and Omron M6 Comfort®, measure BP at the brachial level. The ES...

Journal: :Journal of Information Processing and Management 2005

2015
Hakuo Takahashi Masamichi Yoshika Toyohiko Yokoi

BACKGROUND Allowing patients to measure their blood pressure (BP) at home will be the standard for evaluating the disease state as the process of clinical diagnosis, and it is recognized as having great clinical utility. To measure BP as accurately as possible, innovative techniques have been incorporated into home BP measurement devices. OBJECTIVE The present study aimed to evaluate the perf...

2010
Gianfranco Parati Michael Ochan Kilama Andrea Faini Elisa Facelli Kenneth Ochen Cyprian Opira Shanthi Mendis Jiguang Wang Neil Atkins Eoin O’Brien

Abstract—The management of high blood pressure (BP) is particularly inadequate in low-income countries, where the unavailability of a reliable, durable, and affordable BP-measurement device is a major obstacle to accurate diagnosis. Recognizing this, a World Health Organization committee was established to correct this deficiency by influencing manufacturers to produce a device according to pre...

Journal: :The British journal of general practice : the journal of the Royal College of General Practitioners 2003
Sue M Turnbull Sean P Magennis Chris J Turnbull

Self-monitoring of blood pressure may give a truer estimate of usual blood pressure than readings by a doctor in the surgery, and may save time for health professionals. This study aimed to determine the accuracy of self-monitoring in the surgery using a wrist oscillometric sphygmomanometer (Omron RX). One hundred and seventy-three patients were taught to record their own blood pressure with th...

Journal: :Hypertension 2010
Gianfranco Parati Michael Ochan Kilama Andrea Faini Elisa Facelli Kenneth Ochen Cyprian Opira Shanthi Mendis Jiguang Wang Neil Atkins Eoin O'Brien

The management of high blood pressure (BP) is particularly inadequate in low-income countries, where the unavailability of a reliable, durable, and affordable BP-measurement device is a major obstacle to accurate diagnosis. Recognizing this, a World Health Organization committee was established to correct this deficiency by influencing manufacturers to produce a device according to predetermine...

Journal: :National health statistics reports 2012
Yechiam Ostchega Guangyu Zhang Paul Sorlie Jeffery P Hughes Debra S Reed-Gillette Tatiana Nwankwo Sarah Yoon

OBJECTIVES The mercury sphygmomanometer has been the gold standard used for obtaining blood pressure (BP) for the National Health and Nutrition Examination Survey (NHANES) from 1960 to the present. However, due to environmental concerns and an increased use of automated oscillometric BP devices, NHANES has been exploring an alternative to using the standard mercury sphygmomanometer (mercury) to...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید