نتایج جستجو برای: 103pd source
تعداد نتایج: 418786 فیلتر نتایج به سال:
Monte Carlo simulations are widely used for calculation of the dosimetric parameters of brachytherapy sources. MCNP4C2, MCNP5, MCNPX, EGS4, EGSnrc, PTRAN, and GEANT4 are among the most commonly used codes in this field. Each of these codes utilizes a cross-sectional library for the purpose of simulating different elements and materials with complex chemical compositions. The accuracies of the f...
In 2001, the use of cylindrical coordinates was demonstrated to be more suitable than was the use of polar coordinates for accurate computer calculations during treatment planning for 192Ir intravascular brachytherapy sources. In the present work, we investigated the applicability of cylindrical coordinate-based TG-43U1 parameters for dosimetric evaluation and dose calculations for RadioCoil 10...
In the recommendations of Task Group #43 from American Association of Physicists in Medicine (AAPM TG43), methods of brachytherapy source dosimetry are recommended, under full scattering conditions. However, in actual brachytherapy procedures, sources may not be surrounded by full scattering tissue in all directions. Clinical examples include high-dose-rate (HDR) brachytherapy of the breast or ...
Objective: Brachytherapy sources are widely used for the treatment of cancer. The report of Task Group No. 43 (TG-43) of American Association of Physicists in Medicine is known as the most common method for the determination of dosimetric parameters for brachytherapy sources. The aim of this study is to obtain TG-43 dosimetric parameters for 60Co, 137Cs, 192Ir and 103Pd brachyt...
Theoretical and experimental dosimetric studies have been supplied useful information on the dependence of the brachytherapy source geometry and materials (1-5). Usually, Monte Carlo method is used to define dose distribution function, the radial dose variation, and the dose calculation close to the source in brachytherapy. Chen et al. (6). calculated the distribution of absorbed dose around co...
Introduction: Clinical application of encapsulated radioactive brachytherapy sources has a major role in cancer treatment. In the present research, the effects of different tissue densities on the dose distribution of a 103Pd brachytherapy source in a spherical phantom of 50 cm radius have been studied. Material and Methods: As is well known, absorbed dose in tissue depends to its density, but ...
Preliminary data are given on the LD50 of PdCl2 following different routes of exposure and on the LD50 of PtCl4 following intravenous exposure. The retention, tissue distribution, and excretion of 103Pd and 191Pt in rats was determined following oral, intravenous, intratracheal, and inhalation exposure. The highest retention for both 103Pd and 191Pt was obtained following intravenous dosing, an...
Introduction: 103Pd is a low energy source, which is used in brachytherapy. According to the standards of American Association of Physicists in Medicine, dosimetric parameters determination of brachytherapy sources before the clinical application was considered significantly important. Therfore, the present study aimed to compare the dosimetric parameters of the target source using the water ph...
AIM The aim of this study is to quantify the influence of the photon energy spectrum of brachytherapy sources on task group No. 43 (TG-43) dosimetric parameters. BACKGROUND Different photon spectra are used for a specific radionuclide in Monte Carlo simulations of brachytherapy sources. MATERIALS AND METHODS MCNPX code was used to simulate 125I, 103Pd, 169Yb, and 192Ir brachytherapy sources...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید