نتایج جستجو برای: چشمۀ i 125 مدل 6711

تعداد نتایج: 1184332  

Journal: :Medical physics 2013
Joel Poder Stéphanie Corde

PURPOSE The purpose of this study was to measure the dose distributions for different Radiation Oncology Physics and Engineering Services, Australia (ROPES) type eye plaques loaded with I-125 (model 6711) seeds using GafChromic(®) EBT3 films, in order to verify the dose distributions in the Plaque Simulator™ (PS) ophthalmic 3D treatment planning system. The brachytherapy module of RADCALC(®) wa...

Journal: :Brachytherapy 2014
Argyris Moutsatsos Evaggelos Pantelis Panagiotis Papagiannis Dimos Baltas

PURPOSE To present experimental dosimetry results for the new IsoSeed I25.S17plus (125)I brachytherapy source, in fulfillment of the American Association of Physicists in Medicine recommendation for, at least one, experimental dosimetry characterization of new low-energy seeds before their clinical implementation. METHODS AND MATERIALS A batch of 100 LiF thermoluminescent dosimeter (TLD)-100 ...

2013
J Poder S Corde

In this study, the Plaque SimulatorTM eye plaque brachytherapy planning system was commissioned for ROPES eye plaques and Amersham Health model 6711 Iodine 125 seeds, using TG43-UI data. The brachytherapy module of the RADCALC® independent checking program was configured to allow verification of the accuracy of the dose calculated by Plaque SimulatorTM. Central axis depth dose distributions wer...

Hossein Pourbeigi Mohsen Mashayekhi Galatoiyeh Ramezan Eidi, Ramin Jaberi Seyed Mahmoudreza Aghamiri Seyed Mohsen Hosseini Daghigh Shahab Sheibani

Introduction In order to treat uveal Melanoma , first, radioactive seeds are laid on a silicone- made substance which is called Silastic after that they are inserted in the plaque, and finally, this plaque containing silicone-made substance is stitched to the sclera surface. The dose gradient within the tumor and healthy tissues can be varied due to changing the Silastic thickness between scler...

Journal: :Medical physics 2014
Justus Adamson Yun Yang Titania Juang Kelsey Chisholm Leith Rankine John Adamovics Fang Fang Yin Mark Oldham

PURPOSE To investigate the feasibility of and challenges yet to be addressed to measure dose from low energy (effective energy <50 keV) brachytherapy sources (Pd-103, Cs-131, and I-125) using polyurethane based 3D dosimeters with optical CT. METHODS The authors' evaluation used the following sources: models 200 (Pd-103), CS-1 Rev2 (Cs-131), and 6711 (I-125). The authors used the Monte Carlo r...

Journal: :iranian journal of medical physics 0
ramezan eidi radiation medicine department, shahid beheshti university, tehran, iran

introduction in order to treat uveal melanoma , first, radioactive seeds are laid on a silicone- made substance which is called silastic after that they are inserted in the plaque, and finally, this plaque containing silicone-made substance is stitched to the sclera surface. the dose gradient within the tumor and healthy tissues can be varied due to changing the silastic thickness between scler...

2011
Philip Anthony Colm Delaney Sunil Varughese Longsheng Wang Sylvia M. Draper

New supramolecular luminescent host systems based on 2-cyano-3(4-(diphenylamino)phenyl) acrylic acid (CDPA), a triphenylamine based luminescent acid, and amines (propylamine (1), dimethylaminopyridine, DMAP (2) and (1S,2R)-2-amino-1,2-diphenylethanol (3)) were prepared using a supramolecular approach. For each, the inclusion of amines in the CDPA matrix led to blue shifts in the solid state lum...

2012
Lucas Paixão Alessandro Facure Ana Maria M. Santos Adriano Márcio dos Santos Suely Epsztein Grynberg

In prostate cancer treatment, there is an increasing interest in the permanent radioactive seeds implant technique. Currently, in Brazil, the seeds are imported with high prices, which prohibit their use in public hospitals. A ceramic matrix that can be used as a radioisotope carrier and radiographic marker was developed at our institution. The ceramic matrix is distinguished by the characteris...

Journal: :health scope 0
syed abbas hosseini zahedan university of medical sciences, iran +98-9155408625, [email protected]; zahedan university of medical sciences, iran +98-9155408625, [email protected] syed ali hosseini shiraz university of medical sciences, iran attaullah rakhsh khourshid zahedan university of medical sciences, iran +98-9155408625, [email protected]

objectives this study examined 125i concentrations in the edible parts of five types of plants from different locations on farms with a similar climate. near zahedan, iran. background radioiodine 125i is an environmental contaminant that humans may consume in edible plants. the characteristics of 125i in plants are poorly understood. materials and methods the experiments used a mini-column appr...

F. Atabi, H. Garshasbi, J. Karimi Diba, M.J. Zarei, N. Alirezazadeh,

ABSTRACT Background: Monitoring internal exposure of individuals handling significant amounts of iodine-125 (I-125) for iodination is of great importance. These individuals are potentially exposed to external contamination, and internal contamination through inhalation, ingestion and intact skin absorption, to I-125. Considering radiological toxicity of this radionuclide its monitoring in the w...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید