نتایج جستجو برای: آلیاژ ti 6al 4v

تعداد نتایج: 38731  

2018
Yang Qu Shuang Zheng Rongpeng Dong Mingyang Kang Haohan Zhou Dezhi Zhao Jianwu Zhao

To ensure the biomechanical properties of Ti-24Nb-4Zr-8Sn, stress-shielding effects were compared between Ti-24Nb-4Zr-8Sn and Ti-6Al-4V fixation by using a porcine model. Twelve thoracolumbar spines (T12-L5) of 12-month-old male pigs were randomly divided into two groups: Ti-24Nb-4Zr-8Sn (EG, n = 6) and Ti-6Al-4V (RG, n = 6) fixation. Pedicle screw was fixed at the outer edge of L4-5 vertebral ...

2015
Hossein Maleki-Ghaleh Masoud Hafezi Mohammadreza Hadipour Ali Nadernezhad Ermia Aghaie Yashar Behnamian Noor Azuan Abu Osman Xiaohua Liu

In the current study, a sol-gel-synthesized tricalcium magnesium silicate powder was coated on Ti-6Al-4V alloys using plasma spray method. Composition of feed powder was evaluated by X-ray diffraction technique before and after the coating process. Scanning electron microscopy and atomic force microscopy were used to study the morphology of coated substrates. The corrosion behaviors of bare and...

Journal: :Acta biomaterialia 2008
Chengtie Wu Yogambha Ramaswamy David Gale Wenrong Yang Keqin Xiao Liangchi Zhang Yongbai Yin Hala Zreiqat

Hydroxyapatite (HAp) is commonly used to coat titanium alloys (Ti-6Al-4V) for orthopedic implants. However, their poor adhesion strength and insufficient long-term stability limit their application. Novel sphene (CaTiSiO5) ceramics possess excellent chemical stability and cytocompatibility. The aim of this study is to use the novel sphene ceramics as coatings for Ti-6Al-4V. The sol-gel method w...

Journal: :Biomaterials 2006
Hao Wang Noam Eliaz Zhou Xiang Hu-Ping Hsu Myron Spector Linn W Hobbs

Three different implants, bare Ti-6Al-4V alloy, Ti-6Al-4V alloy coated with plasma-sprayed hydroxyapatite (PSHA), and Ti-6Al-4V alloy coated with electrochemically deposited hydroxyapatite (EDHA), were implanted into canine trabecular bone for 6 h, 7, and 14 days, respectively. Environmental scanning electron microscopy study showed that PSHA coatings had higher bone apposition ratios than thos...

2011
Mari Koike Preston Greer Kelly Owen Guo Lilly Lawrence E. Murr Sara M. Gaytan Edwin Martinez Toru Okabe

This study characterized properties of Ti-6Al-4V ELI (extra low interstitial, ASTM grade 23) specimens fabricated by a laser beam melting (LBM) and an electron beam melting (EBM) system for dental applications. Titanium alloy specimens were made into required size and shape for each standard test using fabrication methods. The LBM specimens were made by an LBM machine utilizing 20 µm of Ti-6Al-...

Journal: :The journal of contemporary dental practice 2007
Khalid A Al Wazzan Ahmad A Al-Nazzawi

AIM The purpose of this in vitro study was to investigate the marginal accuracy and internal fit of complete cast crowns and three-unit fixed partial dentures (FPDs) cast with commercially pure titanium (CPTi) and Titanium-Aluminum-Vanadium alloy (Ti-6Al-4V). METHODS AND MATERIALS CPTi and Ti-6Al-4V alloy were used to cast twelve single crowns and twelve three-unit FPDs. A traveling microscop...

ژورنال: :مواد پیشرفته در مهندسی (استقلال) 0
محمدرضا گرسیوزجزی m.r. garsivaz jazi محمدعلی گلعذار m.a. golozar کیوان رئیسی k. raeissi

در پژوهش حاضر، ترکیب شیمیایی، ضخامت و رفتار تریبوخوردگی لایه اکسیدی بر روی آلیاژ ti-6al-4v، ایجاد شده به روش آندایزینگ1 در محلول h2so4/h3po4 و ولتاژهای بالاتر از ولتاژ شکست دی الکتریک مورد بررسی قرار گرفت. اندازه گیری ضخامت لایه های اکسیدی نشان داد که ضخامت پوشش با افزایش ولتاژ آندایزینگ به صورت خطی افزایش می یابد. تحلیل طیف سنجی پراکنش انرژی (eds2) از فیلم اکسیدی، حضور عناصر فسفر و گوگرد از ال...

ژورنال: :علوم و مهندسی سطح ایران 0

هیدروکسی آپاتیت به علت خواص زیست سازگاری و هدایت استخوانی بالا به عنوان پوشش بر روی آلیاژ تیتانیم استفاده میشود. اما استحکام چسبندگی ضعیف بین هیدروکسی آپاتیت و آلیاژ تیتانیم باعث کاهش  پایداری کاشتنیهایی استفاده شده در بدن به مدت طولانی میشود. در این پژوهش پودر کامپوزیتی هیدروکسی آپاتیت-تیتانیم حاوی 50 درصد وزنی تیتانیم به روش آسیابکاری تهیه و به عنوان ماده اولیه در پلاسما اسپری به منظور ایجاد ...

2018
Gerrit M. Ter Haar Thorsten H. Becker

Current post-process heat treatments applied to selective laser melting produced Ti-6Al-4V do not achieve the same microstructure and therefore superior tensile behaviour of thermomechanical processed wrought Ti-6Al-4V. Due to the growing demand for selective laser melting produced parts in industry, research and development towards improved mechanical properties is ongoing. This study is aimed...

2010
Scott Oppenheimer David C. Dunand

Ti–6Al–4V foams are produced by the expansion of pressurized argon pores trapped in billets created by powder metallurgy. Pore expansion during thermal cycling (840–1030 C, which induces transformation superplasticity in Ti–6Al–4V) improves both the foaming rate (by reducing the flow stress) and the final porosity (by delaying fracture of the pores and subsequent escape of the gas), as compared...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید