نتایج جستجو برای: washout rate
تعداد نتایج: 965526 فیلتر نتایج به سال:
Increased adhesive forces between sickle erythrocytes and endothelial cells (EC) have been hypothesized to play a role in the initiation of vasoocclusion in sickle cell anemia. Erythrocyte/human umbilical vein EC interactions were studied under controlled flow conditions for normal (AA), homozygous sickle cell (SS), sickle cell trait (AS), mechanically injured normal, and "high-reticulocyte con...
Inhibition of the Sodium-Calcium Exchanger by SEA0400 Inhibits Manganese Efflux from Isolated Hearts
Methods Heart Perfusion Protocol Male Sprague Dawley rats were anesthetized. The heart was excised, cannulated, and perfused with Krebs-Henseleit buffer equilibrated with 95% O2 5% CO2 at 370C. A water-filled latex balloon was inserted into the left ventricle and connected to a pressure transducer to record the left ventricular pressure and heart rate. The rate-pressure product (RPP) was used a...
Localization of Tc-99m sestamibi (MIBI) by parathyroid adenomas (PA) is well known. Typically the radionuclide washes out slowly from the PAs located in the neck. Rapid washout from some PAs has been reported. Various hypotheses have been postulated for slow and rapid clearance of MIBI from PAs, located in the neck. However, the washout of MIBI from ectopic parathyroid adenoma (EPA) in not well...
Abstract
A plasmid vector pBK2 was tested for maintenance in Corynebacterium acetoacidophilum and found to be 100% stable for 90 generations. In co-culture experiments in absence of any selection pressure it was able to cause washout of plasmid free cells. Deletion mutagenesis of the plasmid was done to identtfi the regions of DNA responsible for its stable maintenance. This led to the identification of...
This study examines the usage of computational fluid dynamics (CFDs) for estimating the time-elapsed decay of contaminants within a chamber experiencing high Reynolds flow. CFD results were compared with measurements taken at a controlled facility. In addition, parameters of the CFD simulation were examined; namely the effects of turbulence and inertial transport at high Reynolds number ventila...
As a supplement of the droop control, the concept of secondary controlled microgrid (MG) has been extensively studied for voltage and frequency restoration. However, the low band-width communication (LBC) channels are needed to exchange information between the primary and secondary controllers, and the performance of the secondary controller degrades due to the uncertain communication delay and...
We (Innovision ApS, Odense, Denmark) are the manufacturer of the AMIS 2000 medical mass spectrometer system that, using user-specific software and hardware, was adapted to perform MBW. The AMIS 2000-based devices are now considered the ‘‘gold standard’’ device for SF6 LCI measurements in cystic fibrosis patients by opinion leaders in the field [2]. This device has been used in the vast majority...
PURPOSE To evaluate the intraocular pressure washout time after discontinuing brimonidine 0.2% twice daily and latanoprost 0.005% once every evening. METHODS We discontinued brimonidine or latanoprost in a masked fashion from primary open-angle glaucoma or ocular hypertensive patients. The intraocular pressure was measured twice weekly until patients returned to untreated baseline. RESULTS ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید