نتایج جستجو برای: vo2

تعداد نتایج: 3997  

2013
Richard M. Millis Vernon Bond M. Sadegh Asadi Georges E. Haddad Richard G. Adams

Body mass index (BMI) is negatively correlated with cardiorespiratory fitness, measured by maximal or peak oxygen consumption (VO2peak). VO2peak measurements require heavy aerobic exercise to near exhaustion which increases the potential for adverse cardiovascular events. This study tests the hypothesis that VO2 measured at a fixed submaximal workload of 30 W is a surrogate for VO2peak. We stud...

Journal: :Respiratory physiology & neurobiology 2013
I Cano M Mickael D Gomez-Cabrero J Tegnér J Roca P D Wagner

In previous calculations of how the O2 transport system limits .VO2(max), it was reasonably assumed that mitochondrial P(O2) (Pm(O2)) could be neglected (set to zero). However, in reality, Pm(O2) must exceed zero and the red cell to mitochondrion diffusion gradient may therefore be reduced, impairing diffusive transport of O2 and .VO2(max). Accordingly, we investigated the influence of Pm(O2) o...

2015
Camila D. C. Neves Ana Cristina Rodrigues Lacerda Vanessa K. S. Lage Liliana P. Lima Sueli F. Fonseca Núbia C. P. de Avelar Mauro M. Teixeira Vanessa A. Mendonça

BACKGROUND The application of the Shuttle Walking Test (SWT) to assess cardiorespiratory fitness and the intensity of this test in healthy participants has rarely been studied. This study aimed to assess and correlate the cardiorespiratory responses of the SWT with the cardiopulmonary exercise testing (CEPT) and to develop a regression equation for the prediction of peak oxygen uptake (VO2 peak...

2014
GABRIEL J. SANDERS MICHAEL REBOLD COREY A. PEACOCK MEAGAN L. WILLIAMSON ANTONIO S. SANTO JACOB E. BARKLEY

Previous studies have assessed physiologic response while playing video games per manufacturer instructions with participants standing during active video game play and seated during sedentary game play. It is not known whether an assigned seated or standing position affects positional preference and oxygen consumption (VO2) while gaming. The purpose of the study was to assess VO2 and preferenc...

Journal: :Journal of pediatric surgery 1993
R B Hirschl B Grover M McCracken M R Wolfson T H Shaffer R H Bartlett

Liquid ventilation with perfluorocarbon (PFCV) has advantages over conventional gas ventilation (GV) in premature and lung-injured newborn animals. Indirect calorimetric measurement of both oxygen consumption (VO2) and carbon dioxide production (VCO2) during PFCV has not been previously performed. In addition, comparison to indirect calorimetric measurement of VO2 and VCO2 during GV has not bee...

Journal: :The Turkish journal of pediatrics 2004
Yeşim Gürsel Birkan Sonel Haydar Gök Peyman Yalçin

Maximal oxygen uptake (VO2max) has an important place in the assessment of cardiopulmonary fitness. Currently there is insufficient normative data for Turkish children. With this preliminary study, we aimed to set up a normative data for our lab which may also serve as a basis for future large population based studies in Turkey. We assessed the peak oxygen consumption of 80 healthy Turkish chil...

2010
JULIE A. SZABO BRIAN B. PARR JAROD A. HOLT CHRISTOPHER M. DEWITT

The purpose of this study was to evaluate the effect of the E3 Fitness Grips (BioGrip, Inc., Rancho Cordova, CA) on running economy, as measured by oxygen uptake (VO2), and heart rate (HR) during submaximal treadmill running. Eleven subjects, seven female and four male, completed a submaximal running test on a treadmill while VO2 and HR were measured continuously. After achieving steady-state a...

2003
Ross Arena Reed Humphrey Mary Ann Peberdy Michael Madigan

COMPARISON OF OXYGEN UPTAKE ON-KINETIC CALCULATIONS DURING SUBMAXIMAL EXERCISE. Ross Arena, Reed Humphrey, Mary Ann Peberdy, Michael Madigan. JEPonline. 2003;6(2):1-7. The mean response time (MRT) and time constant (TC) are two oxygen uptake (VO2) on-kinetic calculations whose values are presumed to be interchangeable. This study tests the assumption of uniformity among different VO2 on-kinetic...

2004
Candace D. Perkins James M. Pivarnik Matthew R. Green

Background: The reliability and validity of the SensorMedics VmaxST was tested. Methods: Thirty subjects (age = 24.5 ± 4.0 years, height = 174.8 ± 9.8 cm, weight = 70.3 ± 12.6 kg) performed treadmill exercise on three occasions, twice using the VmaxST and once using the SensorMedics 2900 system. Oxygen consumption (VO2; L/min) and heart rate (HR; beats/min) were measured continuously during thr...

Journal: :American journal of physiology. Renal physiology 2008
Roger G Evans Bruce S Gardiner David W Smith Paul M O'Connor

The kidney is faced with unique challenges for oxygen regulation, both because its function requires that perfusion greatly exceeds that required to meet metabolic demand and because vascular control in the kidney is dominated by mechanisms that regulate glomerular filtration and tubular reabsorption. Because tubular sodium reabsorption accounts for most oxygen consumption (Vo2) in the kidney, ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید