نتایج جستجو برای: titanium alloy ti

تعداد نتایج: 109413  

Journal: :Journal of physics 2022

Abstract DC magnetron sputtering was used to deposit titanium (Ti), nitride (TiN), and Ti/TiN multilayer coatings on Ti6Al4V alloy substrates. The have 1, 4, 10, 16, 32 modulation periods respectively. SEM were analyze the surface cross-sectional micro-features of coatings. Electrochemical tests carried out 3.5 wt% NaCl solution at room temperature. resistance coating reaches maximum value, whi...

Journal: :Jurnal Sains Materi Indonesia 2021

EFFECT OF TREATMENT SOLUTION ON THE MICROSTRUCTURE AND MICROHARDNES TERNARY Ni-Al-Nb ALLOY DOPED WITH TITANIUM. Nickel-based superalloys have been widely used in various applications, which require high strength at temperatures. Most types of these is age-hardenable because they γ’ particles' chemical composition Ni3(Al, Ti) γ’-phase matrix. This research will be alloy added alloying elements T...

Journal: :The Journal of prosthetic dentistry 2000
C Ohkubo I Watanabe T Hosoi T Okabe

STATEMENT OF PROBLEM Poor chemical bonding of a denture base resin to cast titanium frameworks often introduces adhesive failure and increases microleakage. PURPOSE This study examined the shear bond strengths of a denture base resin to cast pure titanium, Ti-6Al-4V, and a cobalt-chromium alloy using various adhesive primers. MATERIAL AND METHODS Disks (6.0 mm diameter, 2.5 mm thick) were c...

Journal: :Journal of biomedical materials research. Part B, Applied biomaterials 2009
Anders Palmquist Fredrik Lindberg Lena Emanuelsson Rickard Brånemark Håkan Engqvist Peter Thomsen

The aim of this study was to evaluate the bone response to commercially pure titanium grade I and titanium alloy grade V (90% Ti, 6% Al, and 4% V, depicted Ti6Al4V) after 8 weeks in rabbit tibia. Interference microscopy and scanning electron microscopy were used for surface analyses. Transmission electron microscopy (TEM) was used for evaluation of surface crystallinity and chemistry after prep...

Journal: :Dental materials journal 1984
J Takahashi M Okazaki H Kimura Y Furuta K Yamada

To evaluate a Ni-43.5wt%Ti alloy as a new alloy for cast clasp, the fatigue properties of its castings were examined and compared with those of Co-Cr and Type IV Au alloys castings. The Ni-Ti alloy was cast into a phosphate-bonded investment mold using an argon-arc melting and pressure casting machine. The Ni-Ti alloy castings showed superelasticity in bending tests. Fatigue tests were carried ...

Journal: :Metals 2022

Recently, the development of ?-titanium (Ti) alloys with a low Young’s modulus as human implants has been trend research in biomedical materials. However, designing by conventional experimental methods is too costly and inefficient. Therefore, it necessary to propose method that can efficiently reliably predict microstructures mechanical properties titanium alloys. In this study, machine learni...

2018
Alethea Liens Aurélien Etiemble Pascaline Rivory Sandra Balvay Jean-Marc Pelletier Sandrine Cardinal Damien Fabrègue Hidemi Kato Philippe Steyer Tais Munhoz Jerome Adrien Nicolas Courtois Daniel J Hartmann Jérôme Chevalier

Ti40Zr10Cu36Pd14 Bulk Metallic Glass (BMG) appears very attractive for future biomedical applications thanks to its high glass forming ability, the absence of toxic elements such as Ni, Al or Be and its good mechanical properties. For the first time, a complete and exhaustive characterization of a unique batch of this glassy alloy was performed, together with ISO standard mechanical tests on ma...

Journal: :Contact dermatitis 2016
Simon W Fage Joris Muris Stig S Jakobsen Jacob P Thyssen

Exposure to titanium (Ti) from implants and from personal care products as nanoparticles (NPs) is common. This article reviews exposure sources, ion release, skin penetration, allergenic effects, and diagnostic possibilities. We conclude that human exposure to Ti mainly derives from dental and medical implants, personal care products, and foods. Despite being considered to be highly biocompatib...

2017
H. Habazaki K. Fushimi K. Shimizu P. Skeldon G. E. Thompson

The rapid inward migration of fluoride ions in growing anodic titanium oxide under a high electric field has been elucidated by anodizing a Ti-12 at% silicon alloy, where film growth proceeds at nearly 100% efficiency in selected electrolytes. Further, incorporated silicon species in the anodic film are immobile, acting as marker species. The migration rate of fluoride ions is determined precis...

Journal: :The Journal of chemical physics 2017
Carlos E Hernandez-Tamargo Alberto Roldan Phuti E Ngoepe Nora H de Leeuw

We have proposed a combination of density functional theory calculations and interatomic potential-based simulations to study the structural, electronic, and mechanical properties of pure-silica zeolite Linde Type A (LTA), as well as two titanium-doped compositions. The energetics of the titanium distribution within the zeolite framework suggest that the inclusion of a second titanium atom with...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید