نتایج جستجو برای: time to amplitude converter tac
تعداد نتایج: 10901915 فیلتر نتایج به سال:
In this work, we propose and compare several methods for the visualization and exploration of time-varying volumetric medical images based on the temporal characteristics of the data. The principle idea is to consider a time-varying data set as a 3D volume where each voxel contains a time-activity curve (TAC). We define and appraise three different TAC similarity measures. Based on these measur...
In many signal processing applications, an appropriate measure to compare two signals plays a fundamental role in both implementing the algorithm and evaluating its performance. Several techniques have been introduced in literature as similarity measures. However, the existing measures are often either impractical for some applications or they have unsatisfactory results in some other applicati...
OBJECTIVE The purpose of the study was to assess total antioxidant capacity (TAC) of blood serum in relation with habitual leisure time physical activity (LTPA) and aerobic capacity in a group of 90 men with coronary heart disease (CHD) aged 34.8-77.0 years and in 90 age-matched peers without CHD. METHODS Two spectrophotometric methods were applied to assess TAC: Ferric Reducing Ability of Se...
Growing evidence suggests that GLP-1 protects beta cells against various cellular injuries by modulating autophagy. In this study, we examined whether exendin-4 (Ex-4), a GLP-1 analog, had preventive effects on tacrolimus (Tac)-induced beta cell injury by improving autophagy clearance. Rats with Tac-induced diabetes mellitus exhibited increased autophagy-associated protein expression, light cha...
this paper presents a control strategy for fuel cell/energy storage power generation system during voltage sag conditions. the hybrid dc power sources are connected to grid using power electronic converters include dc-dc converter and grid connected voltage source inverter. the power from hybrid power sources is controlled during voltage sag by designing of control strategy for dc-dc converter....
The n_TOF Collaboration has built and commissioned a high-performance detector for ðn;gÞ measurements called the Total Absorption Calorimeter (TAC). The TAC was especially designed for measuring neutron capture cross-sections of low-mass and/or radioactive samples with the accuracy required for nuclear technology and stellar nucleosynthesis. We present a detailed description of the TAC and disc...
A nine-switch power converter having two sets of out-put terminals was recently proposed in place of the traditional back-to-back power converter that uses 12 switches in total. The nine-switch converter has already been proven to have certain advantages, in addition to its component saving topological feature. Despite these advantages, the nine-switch converter has so far found limited applica...
Culture based phenotypic drug susceptibility testing (DST) for Mycobacterium tuberculosis (TB) is time consuming therefore rapid genotypic methods are increasingly being utilized. We previously developed and evaluated on TB isolates a rapid genotypic TaqMan array card (TAC) that detects mutations in several resistance-associated genes using dozens of primer pairs, probes, and high resolution me...
We experimentally demonstrate a reconfigurable optical converter/encoder for quadrature amplitude modulated (QAM) signals. The system utilizes nonlinear wavelength multicasting, conversion-dispersion delays, and simultaneous nonlinear multiplexing and sampling. We show baud rate tunability (31 and 20 Gbaud) and reconfigurable conversions from lower-order QAM signals to higher-order QAM signals ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید