The precise observation of the angle-frequency spectrum of light filaments in water reveals a scenario incompatible with current models of conical emission (CE). Its description in terms of linear X-wave modes leads us to understand filamentation dynamics requiring a phase- and group-matched, Kerr-driven four-wave-mixing process that involves two highly localized pumps and two X waves. CE and t...
The Advanced Photon Source (APS), a third-generation synchrotron light source, was commissioned in 1995 at Argonne National Laboratory and has been fully operational for beamline users since 1997. The APS storage ring can accommodate up to 68 user beamlines (Figure 1); about 70% of the available beamlines are currently in use by various collaborative access teams (CATs). The 7-GeV synchrotron l...
. . .. . . ._ .. , _.. I We investigate a mechanism responsible for the observed very short times of the photon echo decay (of the order of a.few femtoseconds) . in semiconductors. It is associated with the loss of phase . . memory . , as a result of interaction of the mixed state (associated with interband transitions) with an unscreened random Coulomb potential of the photocarriers or with a ...
There is a significant discrepancy between the values of the proton electric form factor, G(E)(p), extracted using unpolarized and polarized electron scattering. Calculations predict that small two-photon exchange (TPE) contributions can significantly affect the extraction of G(E)(p) from the unpolarized electron-proton cross sections. We determined the TPE contribution by measuring the ratio o...
In fluorescence correlation spectroscopy (FCS) and photon counting histogram (PCH) analysis, the same experimental fluorescence intensity fluctuations are used, but each analytical method focuses on a different property of the signal. The time-dependent decay of the correlation of fluorescence fluctuations is measured in FCS yielding molecular diffusion coefficients and triplet-state parameters...
The recent developments in X-ray detectors have opened new possibilities in the area of time-resolved pump/probe X-ray experiments; this article presents the novel use of a PILATUS detector to achieve X-ray pulse duration limited time-resolution at the Advanced Photon Source (APS), USA. The capability of the gated PILATUS detector to selectively detect the signal from a given X-ray pulse in 24 ...
It is common to have missing genotypes in practical genetic studies, but the exact underlying missing data mechanism is generally unknown to the investigators. Although some statistical methods can handle missing data, they usually assume that genotypes are missing at random, that is, at a given marker, different genotypes and different alleles are missing with the same probability. These inclu...
DAΦNE, the Frascati Φ-factory, is an e+/e– collider with 2 interaction points (IPs). The center of mass energy is 1020 MeV and the design luminosity 4.2 × 1030 cm–2 s–1 in single bunch mode and 5 × 1032 cm–2 s–1 in multibunch mode. Between the possible electromagnetic reactions at the interaction point, single bremsstrahlung (SB) has been selected for the luminosity measurement. The SB high cou...
The manipulation of bubbles and the ignition of microplasma within a 200 nL bubble at atmospheric pressure and in an inert silicone oil environment were achieved. Driven by dielectrophoresis (DEP), bubble generation, transportation, mixing, splitting, and expelling were demonstrated. This process facilitated the preparation of various bubbles with tuneable gas compositions. Different gas bubble...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید