نتایج جستجو برای: semi conductor dosimeter
تعداد نتایج: 150692 فیلتر نتایج به سال:
Monte Carlo water-equivalence study of two PRESAGE® formulations for proton beam dosimetry T Gorjiara, Z Kuncic, J Adamovics and C Baldock 2013 J. Phys.: Conf. Ser. 444 012090 PRESAGE® is a radiochromic solid dosimeter which shows promising potential for 3D proton beam dosimetry. Since an idea dosimeter should be water-equivalent, total depth dose distributions in two PRESAGE® formulations irra...
Spectrophotometric measurements of the Fricke–gelatin–xylenol orange (FGX) gel dosimeter demonstrated reproducible linear dose response up to 25Gy. However, oxidation processes continue post-irradiation, affecting the response of this dosimetry system. Additional oxygenation during preparation increases the sensitivity of the gel but does not improve the auto-oxidation stability of the dosimete...
In recent years, interest in personal noise exposure has expanded beyond a workplace safety measure to become an effective means of investigating physiological effects of the acoustic environment on an individual. This work investigates the effects of the wearer's voice as a possible dominant sound source on body-mounted noise dosimeters and develops methods to improve the application of dosime...
In this paper, radiation effects in protection layers of logical cell of the digital gate in the FPGA for electron and proton rays was simulated Using the FLUKA Code. by using of the Monte Carlo simulation, the electron and proton transport into the logical cell of the digital gate in the FPGA will be studied. In this simulation, the maximum energy of the electrons and protons at the entrance o...
We consider a convex polygonal heat conductor whose inscribed circle touches every side of the conductor. Initially, the conductor has constant temperature and, at every time, the temperature of its boundary is kept at zero. The hot spot is the point at which temperature attains its maximum at each given time. It is proved that, if the hot spot is stationary, then the conductor must satisfy two...
When an alternating electric current flows through a conductor (wire), Electric-E and Magnetic-H fields are created around the conductor. If the length of the conductor is very short compared to a wavelength (<< λ/4), the electric and magnetic fields will decrease dramatically within a distance of one or two wavelengths. However, as the conductor is lengthened, the intensity of the fields...
The timing of a short burst of energy (spike) within a specific time period is used to identify a place in space (input terminal) and/or detect changes in energy or position in the environment. Spike timing is used to determine the motion of an actuator or the activation of a place in space (output terminal). The timing of a spike is specified by a sensor or a time delay memory cell that is pre...
Radiation dosimetry has the purpose of quantifying dose received by occupationally exposed individual. The device used in this process is called a dosimeter, dosimeter can be different situations, for example, to quantify fingers ring model extremity, which focus work. In Brazil, we still do not have standards calibration extremity dosimeters, therefore, work, CASEC recommendations were used, a...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید