The modified square well Potential is combined with perturbed-hard-trimer-chain (PHTC) EOS to predict the solubility parameter of several fluids including alkanes, refrigerants and molten polymers. The performance of the proposed model has been evaluated by predicting the solubility parameter of 12 hydrocarbons,3 refrigerants, and 12 polymers. From the 263 data points for hydrocarbons and refri...
A compressible liquid-drop approach adjusted to uniform matter many-body calculations based on chiral EFT interactions and the experimental nuclear masses is used investigate neutron star crust properties. Eight hamiltonians a representative phenomenological force (SLy4) are confronted. We show that some properties of crust, e.g. clusters mass, charge, asymmetry, mostly determined by symmetric ...
A performance analysis on a vapour compression refrigeration system with various refrigerants mixture of R152a, RE170, R600a, and R290 were done for various mixture ratios and their results were compared with R134a as possible alternative replacement. The results showed that all of the alternative refrigerants investigated in the analysis except R431A, [R 152a (29%), R290 (71%)] have a slightly...
The present work deals with thermodynamic analysis of cascade refrigeration system using ozone friendly refrigerants pair R507A and R23. R507A is azeotropic mixture composed of HFC refrigerants R125/R143a (50%/50% wt.). R23 is a single component HFC refrigerant used as replacement to CFC refrigerant R13 in low temperature applications. These refrigerants have zero ozone depletion potential and ...
In this paper the density and temperature dependencies of surface tension are investigated. Using the Lennard-Jones (12,6), as an effective pair interaction potential, a linear expression is derived for isotherms of g /r2 versus r2 for some normal and ChloroFluoroCarbons (CFCs)</...
Refrigerants that are used in refrigeration systems, cause environmental difficulties such as depletion of ozone layer and greenhouse effect. Thus, we must find substitutes for such refrigerants, in this paper, the effect of refrigerant on the thermodynamics performance of refrigeration cycles are studied. To do this, a refrigerator that has designed for R12, is simulated. Results show that pur...
Refrigerants that are used in refrigeration systems, cause environmental difficulties such as depletion of ozone layer and greenhouse effect. Thus, we must find substitutes for such refrigerants, in this paper, the effect of refrigerant on the thermodynamics performance of refrigeration cycles are studied. To do this, a refrigerator that has designed for R12, is simulated. Results show that pur...
The density of Ga203 liquid in equilibrium with air has been measured at 1800” to 1900°C using an Ir double-bob Archimedean method. The data yield the following description of the density of Gaz03 liquid: p = 4.8374(84)0.00065(12)(T -18S0°C). This density-temperature relationship is compared with the partial molar volume of GazO3 in glasses in the systems CaO-Ga203 -SiOz and Naz0-Ga2O3-SiO2, co...
Effects of temperature on electrical parameters of polysilicon solar cells, fabricated using the phosphorous spin-on diffusion technique, have been studied. The current density–voltagecharacteristics of polycrystalline silicon solar cells were measured in dark at different temperaturelevels. For this purpose, a diode equivalent model was used to obtain saturation current densi...
In the early years, the primary focus of the HVAC industry was simply on finding a refrigerant that would provide effective cooling. Many of the early refrigerants such as sulfur dioxide, methyl chloride and ammonia met that objective but posed safety hazards due to their toxicity or high flammability potential. In the 1930s, chlorofluorocarbon (CFC) refrigerants were introduced as safe alterna...