نتایج جستجو برای: radionuclide purity
تعداد نتایج: 62054 فیلتر نتایج به سال:
This study compares the results of three certified methods, namely differential scanning calorimetry (DSC), the mass balance (MB) method and coulometric titrimetry (CT), in the purity assessment of ferulic acid certified reference material (CRM). Purity and expanded uncertainty as determined by the three methods were respectively 99.81%, 0.16%; 99.79%, 0.16%; and 99.81%, 0.26% with, in all case...
Background The favorable decay properties of 43Sc and 44Sc for PET make them promising candidates for future applications in nuclear medicine. An advantage 43Sc (T1/2 = 3.89 h, Eβ+av = 476 keV [88%]) exhibits over 44Sc, however, is the absence of co-emitted high energy γ-rays. While the production and application of 44Sc has been comprehensively discussed, research concerning 43Sc is still in i...
Radionuclide concentrations in environmental samples such as surface soils, plants and water were evaluated by high purity germanium detector measurements. The contribution rate of short half-life radionuclides such as (132)I to the exposure dose to residents was discussed from the measured values. The highest values of the (131)I/(137)Cs activity ratio ranged from 49 to 70 in the environmental...
Using an innovative time-varying front-end electronics in conjunction with a bulky coaxial high-purity germanium detector, we were able to extend the range of the radionuclide spectra well beyond the analog to digital converter (ADC) saturation point. The electronics automatically conditions the signal for digital-filtering optimization if it is in the ADC voltage range and for time-over-thresh...
The venom of the Eastern coral snake Micrurus fulvius can cause respiratory paralysis in the bitten patient, which is attributable to β-neurotoxins (β-NTx). The aim of this work was to study the biodistribution and lymphatic tracking by molecular imaging of the main β-NTx of M. fulvius venom. β-NTx was bioconjugated with the chelator diethylenetriaminepenta-acetic acid (DTPA) and radiolabeled w...
For sorting, cells or cellular components can specifically be labeled by antibody-coated magnetic beads. We have developed a device for continuous magnetic sorting based on the flow-chamber of a free-flow electrophoresis system. Magnetically labeled particles are injected into a given continuously flowing chamber buffer and pass an inhomogeneous magnetic field, configurated perpendicular to the...
The recent expansion of interventional cardiovascular techniques has stimulated the development of non-invasive cardiac studies, to evaluate the outcome of the interventional therapy. Radionuclide ventriculographic technique provides to quantify global left ventricular systolic/diastolic performance, and evaluate the regional left ventricular wall motion during rest or exercise. This concept wa...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید