Eman Saad Elzanfaly Hala Zaazaa, Hebatallah essam, Khadiga Mohamed Kelani Yasmine Farouk Bassuoni

Factors affecting the performance of polyvinyl chloride based ion selective electrode such as using different cationic exchangers and ionophores as well as sensor fabrication procedures were recently the scope of study by several researchers. This work presents an environment friendly electro-analytical method for the determination of Triprolidine HCl (TRI) and Pseudoephedrine HCl (PSE). A comp...

Arezoo Ghaemi, Zahra Setareh

A highly selective copper (II) coated graphite sensor was prepared by 1,13-bis(8-quinolyl)- 1,4,7,10,13-pentaoxatridecane (kryptofix 5) as a supramolecule ionophore into plasticized polyvinyl chloride (PVC) membrane. The best response characteristic was observed using the membrane composition of PVC = 30.0 mg, dioctyl sebacate (DOS) = 63.5 mg, palmitic acid (PA) = 3.0 mg and kryptofix 5 = 3.5 m...

2012
M. K. Dwivedi Suresh Jain

A PVC-based membrane of 12-crown-4 exhibits good response for Zn2+ in a wide concentration range (7.08  10-5-1.00  10-1 M) with a non-nernstian slope of 20.5 mv per decade of concentration of Zn2+. The response time of sensor is <10 s and the membrane can be used for more than 3 months without observing any divergence. In addition, the proposed sensor exhibits very good selectivity for Zn2+ o...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2002
Abdolkarim Abbaspour Behnam Khajeh

A PVC membrane electrode for lead ions based on phenyl disulfide as the membrane carrier was developed. The electrode exhibits a good Nernstian slope of 29.3 +/- 0.7 mV/decade and a linear range of 2.0 x 10(-6)-1.0 x 10(-2) M for Pb(NO3)2. The limit of detection is 1.2 x 10(-6) M. It has a response time of 45 s and can be used for at least fifty days without any divergence in potential. The pro...

Journal: :The Analyst 2013
Manzar Sohail Roland De Marco Muhammad Tanzirul Alam Marcin Pawlak Eric Bakker

Cyclic voltammetry (CV), synchrotron radiation-X-ray photoelectron spectroscopy (SR-XPS) and near edge X-ray absorption fine structure (NEXAFS) show that oxidation of ferrocene tagged PVC induces an accumulation of high molecular weight polymer at the buried interface between the substrate electrode and the plasticized membrane.

Journal: :Journal of Applied Electrochemistry 2022

Abstract Although ion-selective membrane-based potentiometric sensors have already proved their analytical performance in several fields of life, applicability is still limited practice. Biodegradable, ionic additive-free, polylactic acid-based bulk electrode membrane matrix containing various environmentally friendly polyethylene glycol derivatives as plasticizer was developed for the first ti...

2013
Sima Soheilykhah Ali Sheikhani Alireza Ghorbani Sharif Mohammad M Daevaeiha

A premature ventricular contraction (PVC) is relatively a common event where the heartbeat is initiated by the other pathway rather than by the Sinoatrial node, the normal heartbeat initiator. Determining PVC foci is important for ablation procedure and it can help in pre-procedural planning and potentially may improve ablation outcome. In this study, 12-lead Electrocardiogram (ECG) of 87 patie...

Journal: :The Analyst 2011
Andrew Kavanagh Robert Byrne Dermot Diamond Aleksandar Radu

This work details the use of a 2-component optode membrane which is capable of generating three distinct colours in the presence of Cu(2+) and Co(2+) ions. It has been found that the ionic liquid (IL) trihexyltetradecylphosphonium dicyanamide [P(6,6,6,14)][DCA] can act as plasticizer, ligand and transducer dye when used in poly(vinyl chloride) (PVC) membranes, which significantly simplifies the...