نتایج جستجو برای: phantom ct ct number

تعداد نتایج: 1305532  

2015
Kazuhiko Hayashi Fumiaki Isohashi Yuichi Akino Nobuhide Wakai Seiji Mabuchi Osamu Suzuki Yuji Seo Yuki Ootani Iori Sumida Yasuo Yoshioka Tadashi Kimura Kazuhiko Ogawa

We adapted the deformable image registration (DIR) technique to accurately calculate the cumulative intracavitary brachytherapy (ICBT) and external beam radiotherapy (EBRT) rectal dose for treating uterine cervical cancer. A total of 14 patients with primary cervical cancer radically treated with ICRT and EBRT were analysed using the Velocity AI(TM) software. Computed tomography (CT) images wer...

Journal: :Medical physics 2002
M Partridge M Ebert B M Hesse

A method of reconstructing three-dimensional, in vivo dose distributions delivered by intensity-modulated radiotherapy (IMRT) is presented. A proof-of-principle experiment is described where an inverse-planned IMRT treatment is delivered to an anthropomorphic phantom. The exact position of the phantom at the time of treatment is measured by acquiring megavoltage CT data with the treatment beam ...

Journal: :iranian journal of public health 0
seyed ali reza hosseini office for clinical trials, food and drug organization, ministry of health and medical education, tehran, iran ; food and drug research center, food and drug organization, ministry of health and medical education, tehran, iran. shadan darbooy akram salimi

clinical trial committee (ctc) has been established in food and drug organization (fdo), in 2003 to assure efficacy and safety of all types of medicinal products which are meant to be registered in iran drug list and/or obtain market authorization.all clinical trial files, meeting minutes and databases in ctc secretariat in fdo were reviewed. relevant information and data extracted, analyzed an...

Journal: :Nihon Hoshasen Gijutsu Gakkai zasshi 2011
Ichiro Fujimura Katsuhiro Ichikawa Shoichi Terakawa Takanori Hara Yohei Miura

For head computed tomography (CT), non-helical scanning has been recommended even in the widely used multi-slice CT (MSCT). Also, an acute stroke imaging standardization group has recommended the non-helical mode in Japan. However, no detailed comparison has been reported for current MSCT with more than 16 slices. In this study, we compared the non-helical and helical modes for head CT, focusin...

2011
MF Chan J Yang Y Song C Burman P Chan S Li

PURPOSE The imaging characteristics of two popular kV cone-beam CT (CBCT) and two MVCT systems utilised in image-guided radiation therapy (IGRT) were evaluated. MATERIALS AND METHODS The study was performed on Varian Clinac iX, Elekta Synergy S, Siemens Oncor, and Tomotherapy. A CT phantom (Catphan-504, Phantom Laboratory, Salem, NY) was scanned for measurements of image quality including ima...

2012
Kosuke Matsubara Haruka Koshida Keita Sakuta Tadanori Takata Junsei Horii Hiroji Iida Kichiro Koshida Katsuhiro Ichikawa Osamu Matsui

One-hundred-and-twenty-eight-section dual X-ray source computed tomography (CT) systems have been introduced into clinical practice and have been shown to increase temporal resolution. Higher temporal resolution allows low-dose spiral mode at a high pitch factor during CT coronary angiography. We evaluated radiation dose and physical image qualities in CT coronary angiography by applying high-p...

2016
Silvano Gnesin Paulo Leite Ferreira Jerome Malterre Priscille Laub John O. Prior Francis R. Verdun

Aim. Similar to PET, absolute quantitative imaging is becoming available in commercial SPECT/CT devices. This study's goal was to assess quantitative accuracy of activity recovery as a function of image reconstruction parameters and count statistics in a variety of phantoms. Materials and Methods. We performed quantitative 99mTc-SPECT/CT acquisitions (Siemens Symbia Intevo, Erlangen, Germany) o...

2017
Om Prakash Gurjar Radha Kishan Paliwal Surendra Prasad Mishra

The aim is to study the density, isodose depths, and doses at different points in slab-pinewood-slab (SPS) phantom, solid phantom SP34 (made up of polystyrene), and chest level of actual patient for developing heterogeneous chest phantom mimicking thoracic region of human body. A 6 MV photon beam of field size of 10 cm × 10 cm was directed perpendicular to the surface of computed tomography (CT...

2002
Stephen J. Howlett Tomas Kron

This paper presents an anthropomorphic phantom study of dose delivered to a specific point during tangential breast irradiation to verify monitor unit calculations. Measurements were made using a 0.6 cc Farmer type cylindrical ionization chamber in the phantom and compared to calculations made on a three-dimensional radiotherapy treatment planning system using single digitized contour through t...

2007
Noriyuki Arai Shigeru Nakamura Shigeru Suzuki Takashi Matsushita

Introduction: Accurate assessment of cup orientation is important for evaluation of outcome after total hip arthroplasty (THA). The orientation is clinically described as a combination of inclination angle and version angle. Measurements of these angles based on plane radiographs are inaccurate, because no solution exists for perfect positioning of the pelvis, as Liaw(1) stated. Computed tomogr...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید