نتایج جستجو برای: ph sensor
تعداد نتایج: 353417 فیلتر نتایج به سال:
An esterified pillar[5]arene has been incorporated into a PVC electrochemical membrane. The resulting pH-responsive sensor functions in the range of pH 1 to 4 in a non-linear manner.
A carbon dot-based fluorescence turn-on sensor for hydrogen peroxide (H2O2) with a photo-induced electron transfer mechanism was developed. The sensor exhibits good selectivity, sensitivity, and rapid response to H2O2 with a detection limit of 84 nM. The sensor maintains excellent sensing performance over a wide pH range.
Telah dilakukan perancangan sistem kontrol kualitas air pada akuarium ikan hias tawar dan monitoring via Telegram. Parameter yang digunakan yaitu kekeruhan, suhu pH. Nilai ambang batas kekeruhan 25 NTU, 28 O C pH 6 hingga 8. Sensor pengujian ini sensor turbidity SEN0198, DS18B20 sensor. Alat pengontrol berupa pompa filter, kipas DC buffer . Data diproses oleh mikrokontroler Arduino Uno dengan m...
The pH sensor exploits the phenomenon of upconversion luminescence and is based on a hydrogel matrix containing (a) nanorods of the NaYF(4):Er,Yb type that can be excited with 980-nm laser light to give a green and red (dual) emission, and (b) a longwave absorbing pH probe that causes a pH-dependent inner filter effect.
The naphthalimide derivative 1 was designed as a fluorescence PET sensor for Zn(II); 1 showed excellent selectivity for Zn(II) at pH 7.4, even in the presence of other competitive cations, the emission, being pH independent above pH 3.5, was switched on upon Zn(II) recognition.
Maintaining Dissolved Oxygen (DO) levels in the hydroponic plant nutrient solutions can be done using nanobubble technology. Manual monitoring time-consuming and measurement results are less accurate. Therefore, a system is needed to monitor air temperature, humidity, water pH, concentrations, DO levels. Several stages this research preparation, design, sensor calibration, implementation. Air t...
in order to study the cu(ii) ion selective electrode, an optimized membrane was prepared by mixing of 30 mg of pvc powdered, 5 mg of considered ionophore, 60 mg of plasticizer and 5 mg of additive. the sensor showed a near nernstian response for cu(ii) ions over a concentration range from 1.0×0-6 –1.0×0-2 m with a slope of 28.90.5 mv per concentration decade with a working ph range of 3.5-6.3. ...
a sensor, based on multi-wall carbon nanotubes modified glassy carbon electrode (mwcnt/gce), was developed for determination of fenitrothion. determining the surface area of mwcnt/gce showed that this surface is three times more active than that of a glassy carbon electrode. the experimental parameters, such as the amount of mwcnts, ph of the fenitrothion solution, preconcentration potential an...
Autonomous sensors are required for a comprehensive documentation of the changes in the marine carbon system and thus to differentiate between its natural variability and anthropogenic impacts. Spectrophotometric determination of pH – a key variable of the seawater carbon system – is particularly suited to achieve precise and drift-free measurements. However, available spectrophotometric instru...
نمودار تعداد نتایج جستجو در هر سال