نتایج جستجو برای: pedicle screw

تعداد نتایج: 19650  

Journal: :iranian journal of neurology 0
morteza faghih-jouibari department of neurosurgery, shariati hospital, tehran university of medical sciences, tehran, iran keisan moazzeni department of neurosurgery, shariati hospital, tehran university of medical sciences, tehran, iran amir amini-navai department of neurosurgery, shariati hospital, tehran university of medical sciences, tehran, iran sara hanaei department of neurosurgery, shariati hospital, tehran university of medical sciences, tehran, iran sina abdollahzadeh pasteur hospital, bam university of medical sciences, bam, iran ramin khanmohammadi department of neurosurgery, shariati hospital, tehran university of medical sciences, tehran, iran

background: this study aimed to investigate the pedicle dimension and angulation in cervicothoracic junction (ctj) using the findings of computed tomographic (ct) to help accurate insertion of pedicular screw. methods: forty three patients with high quality ct images of ctj were evaluated. pedicle width (pw), pedicle height (ph), pedicle axis length (pal), transverse angle (ta) and sagittal ang...

2013
JINGCHEN LIU YE LI YUNTAO WU

The present study aimed to evaluate the effect of using one-stage posterior C2 and C3 pedicle screw fixation or combined anterior C2-C3 fusion in the treatment of unstable hangman's fracture. A total of 13 patients with unstable hangman's fractures underwent C2 and C3 pedicle screw fixation, lamina interbody fusion or combined anterior C2-C3 fusion and imaging examinations to evaluate the fract...

2008
Justin F. Fraser Ron Von Jako John A. Carrino Roger Härtl

BACKGROUND This cadaveric study compared efficacy and safety of an electromagnetic (EM) guidance system versus conventional fluoroscopy for percutaneous pedicle screw fixation. As percutaneous pedicle screw fixation becomes increasingly common in spinal surgery, intraoperative imaging systems that maximize efficiency while minimizing radiation exposure and inaccurate trajectories will be progre...

2013
Da Liu Yi Zhang Bo Zhang Qing-yun Xie Cai-ru Wang Jin-biao Liu Dong-fa Liao Kai Jiang Wei Lei Xian-ming Pan

BACKGROUND It was reported that expansive pedicle screw (EPS) and polymethylmethacrylate-augmented pedicle screw (PMMA-PS) could be used to increase screw stability in osteoporosis. However, there are no studies comparing the two kinds of screws in vivo. Thus, we aimed to compare biomechanical and interfacial performances of EPS and PMMA-PS in osteoporotic sheep spine. METHODOLOGY/PRINCIPAL F...

2013
WEIJIE HUANG TAO LUO

The present study aimed to discuss the method and effect of posterior internal fixation of thoracolumbar fractures strengthened by the vertical stress pedicle screw fixation of fractured vertebrae. Patients with single thoracolumbar fractures were examined retrospectively. Fourteen patients (group A) had been treated with vertical stress pedicle screw fixation of a fractured vertebra and sixtee...

2009
Suat E. Çelik Bilal Kelten Recai Gökcan Ahmet Cevri Yildiz

The purpose of our study was to determine the diagnostic power of three-dimensional reformatted multi-slice computerized tomography (CT) images on misplaced pedicle screws in spinal surgery. Eighty-four consecutive patients with 458 screws in situ were investigated prospectively using both axial CT slices and reformatted images after operation by two blinded investigators. All the screw misplac...

Journal: :Journal of orthopaedic surgery 2014
Chun Ee Tan Margaret Woon Man Fok Keith Dip Kei Luk Kenneth Man Chee Cheung

PURPOSE. To evaluate the insertion torque and pullout strength of pedicle screws with or without repositioning. METHODS. 20 fresh porcine lumbar vertebrae of similar size were used. The entry point was at the site just lateral and distal to the superior facet joint of the vertebra, and to a depth of 35 mm. A 6.2-mm-diameter, 35-mm-long pedicle screw was inserted parallel to the superior end pla...

2010
Robert Green Watkins Akash Gupta

OBJECTIVE To determine if image-guided spine surgery is cost effective. METHODS A prospective case series of the first 100 patients undergoing thoracolumbar pedicle screw instrumentation under image-guidance was compared to a retrospective control group of the last 100 patients who underwent screw placement prior to the use of image-guidance. The image-guidance system was NaviVision (Vector V...

2017
He-Xuan Di Feng-Yu Liu Si-Dong Yang Hui Wang Da-Long Yang Wen-Yuan Ding

RATIONALE Kummell disease is described as avascular necrosis of a vertebral body that occurred in a delayed fashion after a minor trauma. Anterior, posterior, and anterior-posterior approaches have been reported. Nevertheless, there is no standard treatment for patients with Kummell disease. PATIENT CONCERNS We reported a successful cement-augmented pedicle screw placement in a patient with K...

Journal: :Spine 2016
Keitaro Matsukawa Takashi Kato Yoshiyuki Yato Hiroshi Sasao Hideaki Imabayashi Naobumi Hosogane Takashi Asazuma Kazuhiro Chiba

STUDY DESIGN Retrospective study evaluating cranial facet joint violation (FJV) by pedicle screws. OBJECTIVE The aim of the study was to determine the incidence and risk factors of FJV following screw placement via cortical bone trajectory (CBT). SUMMARY OF BACKGROUND DATA CBT is a new minimally invasive technique for lumbar pedicle screw insertion that minimizes muscle dissection. Insertin...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید