نتایج جستجو برای: monte carlo fluka
تعداد نتایج: 72691 فیلتر نتایج به سال:
Monte Carlo method is the most accurate method for simulation of radiation therapy equipment. The linear accelerators (linac) are currently the most widely used machines in radiation therapy centers. Monte Carlo modeling of the Siemens Primus linear accelerator in 6 MeV beams was used. Square field size of 10 × 10 cm2 produced by the jaws was compared with TLD. Head simulation of Siemens accele...
aquaporins are integral membrane proteins from a larger family of major intrinsic proteins that formpores in the membrane of biological cells. aquaporins form tetramers in the cell membrane with eachmonomer acting as a water channel.in this research, the aqp4 tetramer was modeled from its pdbstructure file, then, we have performed the intraction of aquaporin4 in different temperatures (298k,300...
in this paper, we calculate electron and hole impactionization coefficients in in0.52al0.48as using a monte carlo modelwhich has two valleys and two bands for electrons and holesrespectively. also, we calculate multiplication factor for electronand hole initiated multiplication regimes and breakdown voltagein in0.52al0.48as pin avalanche photodiodes. to validate themodel, we compare our simulat...
in this work, based on experimental observations and exact theoretical predictions, the kinetic scheme of raft polymerization is extended to a wider range of reactions such as irreversible intermediate radical terminations and reversible transfer reactions. the reactions which have been labeled as kinetic scheme are the more probable existing reactions as the theoretical point of view. the deta...
background: physical wedges are still widely used as beam modifiers in external beam radiotherapy. however the presence of them in the beam trace may cause beam hardening which may not be considered in many treatment planning systems. the aim of this study is to investigate the beam hardening effect generated by physical wedges via different beam quality indexes as photon spectrum, half value l...
This Note describes calculations of the shielding necessary to reduce the dose rate to less than 0.05 mrem/h when synchrotron radiations emitted by the LCLS electrons beam hit a worst type scattering target located in the hard X-ray line. The calculations were performed using the FLUKA Monte-Carlo code and as well as the STAC8 analytical code. The photon spectrum used as a source term correspon...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید