نتایج جستجو برای: metal on polyethylene

تعداد نتایج: 8529332  

Journal: :Gastrointestinal endoscopy 1995
S O'Brien A R Hatfield P I Craig S P Williams

Effective palliation of malignant biliary obstruction with conventional 10 or 12 French gauge straight polyethylene endoprostheses is limited by stent occlusion, which typically occurs four to five months after insertion. Short term follow up studies of self expanding metal stents (Wallstent, Schneider, UK) in the treatment of patients with malignant biliary obstruction have shown that their us...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه شیراز - دانشکده علوم 1390

a novel silver (ag) nanocomposite electrode was proposed that fabricated from metal nanostructures and ionic liquids. the combined application of unique properties of nanomaterials and ionic liquids in the design of this ag nanocomposite results in electrodes with interesting advantages compared to the conventional metal disk electrode. in the first part of this thesis, the elecrocatalytic eff...

2016
Patrick Leung James C. Kudrna

The development of pseudotumors is not uncommon with metal-on-metal total hip arthroplasty. Pseudotumors that dissect into the retroperitoneal space can cause symptoms of nerve compression. We describe a case of a 53-year-old male with a metal-on-metal total hip arthroplasty who developed mild symptoms of a femoral nerve neuropathy 6 years postoperatively. Revision arthroplasty to a ceramic-on-...

Journal: :Science 2011
Y Liao R Pourzal M A Wimmer J J Jacobs A Fischer L D Marks

Arthritis is a leading cause of disability, and when nonoperative methods have failed, a prosthetic implant is a cost-effective and clinically successful treatment. Metal-on-metal replacements are an attractive implant technology, a lower-wear alternative to metal-on-polyethylene devices. Relatively little is known about how sliding occurs in these implants, except that proteins play a critical...

Journal: :The Journal of bone and joint surgery. British volume 2009
S A Sexton W L Walter M P Jackson R De Steiger T Stanford

Dislocation is a common reason for revision following total hip replacement. This study investigated the relationship between the bearing surface and the risk of revision due to dislocation. It was based on 110 239 primary total hip replacements with a diagnosis of osteoarthritis collected by the Australian Orthopaedic Association National Joint Replacement Registry between September 1999 and D...

Journal: :The Journal of bone and joint surgery. British volume 1989
G R Scuderi J N Insall R E Windsor M C Moran

The survivorship method of analysis has been used to compare the failure rate and overall success of 1,430 cemented primary total knee arthroplasties performed at The Hospital for Special Surgery over a 15-year period. There were 224 total condylar prostheses with a polyethylene tibia, 289 of the posterior stabilised type with an all polyethylene tibia, and 917 posterior stabilised with a metal...

2015
Ryan Gupta Duy Phan Ran Schwarzkopf

BACKGROUND Metal hypersensitivity is an uncommon complication after total knee arthroplasty (TKA) that can lead to significant functional impairment and aseptic prosthesis failure. CASE REPORT We describe a 70-year-old patient who presented with persistent pain, swelling, and instability 2 years after a primary TKA. The patient had a history of metal hypersensitivity following bilateral metal...

Journal: :Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca 2015
M Vrbka D Nečas J Bartošík M Hartl I Křupka A Galandáková J Gallo

PURPOSE OF THE STUDY The wear of articular surfaces is considered one of the most important factors limiting the life of total hip arthroplasty (THA). It is assumed that the particles released from the surface of a softer material induce a complex inflammatory response, which will eventually result in osteolysis and aseptic loosening. Implant wear is related to a friction coefficient which depe...

2015
Nicholas A. Beckmann Tobias Gotterbarm Moritz M. Innmann Christian Merle Thomas Bruckner J. Philippe Kretzer Marcus R. Streit

BACKGROUND The optimal type of bearing for hip arthroplasty remains a matter of debate. Ceramic-on-polyethylene (CoP) bearings are frequently used in younger and more active patients to reduce wear and increase biocompatibility compared to Metal-on-Polyethylene (MoP) bearings. However, in comparison to metal heads, the fracture risk of ceramic heads is higher. In addition, ceramic head fracture...