Current-limiting reactors are widely used in industrial electrical grids to reduce the current amplitude equipment and stabilize voltage on busbar during short circuits. Their application is distinguished by high technical economic efficiency. However, mechanical damage has been observed within extensive with many induction motors internal synchronous generators. The article analyses a case stu...

2015
Greeshma Thankam Philip Reena Rajan

A step-up bridgeless single phase ac-dc power factor correction (PFC) rectifier based on sepic topology is proposed for high voltage battery charger application. The proposed topology consists of common input stage and parallel output stages. It utilizes one control signal over the whole line cycle. In addition, the proposed converter exhibits low inrush current and low magnetic emissions as cl...

2012
H. Canacsinh J. Fernando A. da Silva Sónia Ferreira Pinto Luis M. Redondo João Santana

The purpose of this paper is to present and discuss a general HV topology of the solid-state Marx modulator, for unipolar or bipolar generation connected with a step-up transformer to increase the output voltage applied to a resistive load. Due to the use of an output transformer, discussion about the reset of the transformer is made to guarantee zero average voltage applied to the primary. It ...

2014
Ann Mary Abraham

High Torque Low Current (HTLC) Starter is the new innovative motor soft starter system. This is a motor starting method for high inertia loads using a low voltage drive with input and output transformers to control motor torque and limit current when starting a medium/high voltage motor. The HTLC is a solution to motor starting problems where Direct on Line (DOL) or “Across the Line” starting i...

2017
K. N. Dinesh Babu P. K. Gargava

Energization of a transformer results in sudden flow of current which is an effect of core magnetization. This current will be dominated by the presence of second harmonic, which in turn is used to segregate fault and inrush current, thus guaranteeing proper operation of the relay. This additional security in the relay sometimes obstructs or delays differential protection in a specific scenario...

2010
A. Nemati

A novel ZVZCS isolated dual series-resonant active-clamp dc–dc converter is proposed to obtain high efficiency. The proposed converter employs an active-clamp technique, while a series-resonant scheme controls the output voltage with the complementary pulse width modulation controller. The active-clamp circuit serves to recycle the energy stored in the leakage inductance or the magnetizing indu...

2001
MLADEN KEZUNOVIC BOGDAN KASZTENNY

The more sophisticated a protection algorithm, the more information on both steady-state and transient behavior of a protected element required for proper designing, setting and testing of a given relay. In the case of a power transformer, the most important phenomena to be modeled from the standpoint of protective relaying are: magnetizing inrush including initial, recovery and sympathetic inr...

Wind powers are very unstable in voltage fluctuations, especially in short circuit error and sharp and sudden voltage drops, which one of its main reasons is the use of induction generators in these power plants and thus need to reactive power and high magnetizing current. To improve the ride_through voltage from WECS in error conditions and damping the oscillations of the induction generator r...

Journal: :IEEE Access 2022

This paper addresses the black start of medium voltage distribution networks (MV-DNs) by a battery energy storage system (BESS). The BESS consists two-level source inverter interfacing MV-DN which has limited overcurrent capability. On other hand, normally includes several step-up and step-down transformers that are drawing sympathetic inrush current in energizing stage. Therefore, major diffic...