نتایج جستجو برای: iodide ion selective electrode

تعداد نتایج: 461721  

Journal: :Bulletin of the Chemical Society of Japan 1979

In this research, a coated graphite electrode was constructed for determination of Mg2+ in pharmaceutical supplements. The designed sensor demonstrates an ideal Nernstian slope (30.1 mV. Decade-1) over a wide concentration range (1×10-6- 1×10-1 Mol L-1). The selectivity of the sensor was evaluated over 16 different cations by matched potential method and no serious interference was observed fro...

2012
Reza Ansari

Potentiometric sensor based on commercial pencil graphite electrodes coated with polyaniline (PAni) composite with Eosin Y (EY) termed as PGE/PAni-EY have been developed for potentiometric determination of silver ion. The electrode exhibited linear response with Nernstian slope of 57.6±0.8 mV per decade within the range of 1.0×10 to 1.0×10 M with limit of detection 6.5×10 M silver ion. Fast and...

2011
Sonika Tyagi Himanshu Agarwal Saiqa Ikram Mukesh Kumar Gupta Sanjay Singh

The aim of this study was to construct and characterize an ion selective electrode for the potentiometric determination of thorium ions. On hand study we introduced a new calixarene molecule p-tert-butyl-thiacalix[4]arene derivative as ionophore for thorium(IV) selective polymeric membrane electrode. Due to the decisive role of solvent mediators, we fabricated membranes with the plasticizers DB...

Journal: :Clinical chemistry 1977
J M Grima M J Brand

We assessed the magnitude of the errors in ionized-calcium measurements resulting from changes in electrolyte composition for three different ion-selective electrodes: the Orion Model 93-20, the Radiometer F2112, and the Simon neutral carrier membrane electrode. We attempted to distinguish between errors arising from changes in calcium ion activity and those due to interferences in the electrod...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2008
Naoya Nishi Hiroshi Murakami Yukinori Yasui Takashi Kakiuchi

The phase-boundary potential at the interface between an aqueous KCl solution (W) and a hydrophobic room-temperature ionic liquid (RTIL), trioctylmethylammonium bis(nonafluorobutylsulfonyl)imide ([TOMA(+)][C(4)C(4)N(-)]), containing dicyclohexano-18-crown-6 (DCH18C6), shows the nernstian response to K(+) in W within a polarized potential window of 500 mV between [TOMA(+)][C(4)C(4)N(-)] and W, d...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید