نتایج جستجو برای: gafchromic film

تعداد نتایج: 90975  

Journal: :Dento maxillo facial radiology 2013
A Al-Okshi M Nilsson A Petersson M Wiese C Lindh

OBJECTIVES To demonstrate the feasibility of GafChromic(®) XR-QA2 (ISP Corp., Wayne, NJ) as a dosemeter when performing measurements of the effective dose from three cone beam CT (CBCT) units and to compare the doses from examinations of three common dental clinical situations. A second aim was to compare the radiation doses for three digital panoramic units with the doses for the CBCT units. ...

2016
Hideharu Miura Shuichi Ozawa Fumika Hosono Naoki Sumida Toshiya Okazue Kiyoshi Yamada Yasushi Nagata

Radiochromic films are important tools for assessing complex dose distributions. Gafchromic EBT-XD films have been designed for optimal performance in the 40-4,000 cGy dose range. We investigated the dosimetric characteristics of these films, including their dose-response, postexposure density growth, and dependence on scanner orientation, beam energy, and dose rate with applications to high-do...

2014
Mara Severgnini Mario de Denaro Marina Bortul Cristiana Vidali Aulo Beorchia

Intraoperative electron radiation therapy (IOERT) cannot usually benefit, as conventional external radiotherapy, from software systems of treatment planning based on computed tomography and from common dose verify procedures. For this reason, in vivo film dosimetry (IVFD) proves to be an effective methodology to evaluate the actual radiation dose delivered to the target. A practical method for ...

Journal: :Medical physics 2012
David Lewis Andre Micke Xiang Yu Maria F Chan

PURPOSE Radiochromic film provides dose measurement at high spatial resolution, but often is not preferred for routine evaluation of patient-specific intensity modulated radiation therapy (IMRT) plans owing to ease-of-use factors. The authors have established an efficient protocol that combines calibration and measurement in a single scan and enables measurement results to be obtained in less t...

Journal: :Radiation protection dosimetry 2016
J Nilsson Althén M Sandborg

The aim of this work was to verify the indicated maximum entrance surface air kerma (ESAK) using a GE Innova IGS 520 imaging system during cardiac interventional procedures. Gafchromic XR RV3 films were used for the patient measurements to monitor the maximum ESAK. The films were scanned and calibrated to measure maximum ESAK. Thermoluminescent dosemeters were used to measure the backscatter fa...

2008
Olivia Amanda García‐Garduño Miguel Ángel Celis José Manuel Lárraga‐Gutiérrez Sergio Moreno‐Jiménez Arnulfo Martínez‐Dávalos Mercedes Rodríguez‐Villafuerte

Micro-multileaf collimator systems coupled to linear accelerators for radioneurosurgery treatments require a rigorous dosimetric characterization in order to be used in 3D conformal and intensity modulated stereotactic radiosurgery and radiotherapy applications. This characterization involves high precision measurements of leaf transmission, leakage and beam penumbra through the collimation sys...

2015
Marcus Sonier Matt Wronski Collins Yeboah

Lens dose is a concern during the treatment of facial lesions with anterior electron beams. Lead shielding is routinely employed to reduce lens dose and minimize late complications. The purpose of this work is twofold: 1) to measure dose pro-files under large-area lead shielding at the lens depth for clinical electron energies via film dosimetry; and 2) to assess the accuracy of the Pinnacle tr...

2016
Ning Wen Siming Lu Jinkoo Kim Yujiao Qin Yimei Huang Bo Zhao Chang Liu Indrin J Chetty

PURPOSE The purpose of this study is to evaluate the dosimetric uncertainty associated with Gafchromic™ (EBT3) films and establish a practical and efficient film dosimetry protocol for Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiotherapy (SBRT). METHOD AND MATERIALS EBT3 films were irradiated at each of seven different dose levels between 1 and 15 Gy with open fields and standar...

2013
Valeria Casanova Borca Massimo Pasquino Giuliana Russo Pierangelo Grosso Domenico Cante Piera Sciacero Giuseppe Girelli Maria Rosa La Porta Santi Tofani

Radiochromic film has become an important tool to verify dose distributions in highly conformal radiation therapy such as IMRT. Recently, a new generation of these films, EBT3, has become available. EBT3 has the same composition and thickness of the sensitive layer of the previous EBT2 films, but its symmetric layer configuration allows the user to eliminate side orientation dependence, which i...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید