نتایج جستجو برای: fat phantom

تعداد نتایج: 136765  

2014
Kim J. Boström Marc H. E. de Lussanet Thomas Weiss Christian Puta Heiko Wagner

Amputation often leads to painful phantom sensations, whose pathogenesis is still unclear. Supported by experimental findings, an explanatory model has been proposed that identifies maladaptive reorganization of the primary somatosensory cortex (S1) as a cause of phantom pain. However, it was recently found that BOLD activity during voluntary movements of the phantom positively correlates with ...

Journal: :Indian journal of experimental biology 2010
P S Pandian Megha Singh

Laser backscattering from biological tissues depends on their composition and blood flow. The onset of the tissue abnormalities is associated with the change in composition at a specific location which may affect laser backscattering. The objective of the present work is to detect the compositional changes in tissue-equivalent phantom of fat, prepared by mixing paraffin wax with wax colors, and...

2017
Sara Fouad Reda Ghoname Abd Elmonem Elmahdy Abd Elhalim Zekry

An ultra-wideband (UWB) microwave system for breast cancer detection is presented. The proposed system includes monocycle pulse generator, antipodal Vivaldi antenna, breast model, and calibration algorithm for tumor detection. Firstly, our pulse generator employs transmission gate in glitch generator to achieve several advantages such as low power consumption and low ringing level. Secondly, th...

Journal: :Journal of rehabilitation medicine 2009
Roberto Casale Francesco Ceccherelli Alaa Abd Elaziz Mohamed Labeeb Gabriele E M Biella

OBJECTIVE To ascertain the existence of contralateral painful muscle areas mirroring phantom pain and to evaluate the short-term effects of anaesthetic vs saline, injected contra notlaterally to control phantom and phantom limb pain. DESIGN Double-blinded cross-over study. SETTING Inpatients; rehabilitation institute. PARTICIPANTS Eight lower limb amputees with phantom limb pain in the pa...

Journal: :Physics in medicine and biology 2014
Mats Persson Ben Huber Staffan Karlsson Xuejin Liu Han Chen Cheng Xu Moa Yveborg Hans Bornefalk Mats Danielsson

Photon-counting detectors are promising candidates for use in the next generation of x-ray computed tomography (CT) scanners. Among the foreseen benefits are higher spatial resolution, better trade-off between noise and dose and energy discriminating capabilities. Silicon is an attractive detector material because of its low cost, mature manufacturing process and high hole mobility. However, it...

2007
C. N. Prince N. Oesingmann K. McGorty V. S. Lee

Introduction Dual gradient echo In-Phase(IP) and Opposed-Phase(OP) imaging (or Dixon’s technique) is used routinely in body imaging for a broad range of clinical diagnoses, including hepatic steatosis, adenomas and renal angiomyolipomas. This sequence can also be used to quantify the fat content of pathology. IP/OP imaging is based upon periodic addition (IP) or cancellation (OP) of fat and wat...

Journal: :iranian journal of medical physics 0
ali aghaebrahimian department of physics, isfahan university of technology, isfahan, iran mohammad hassan alamatsaz department of physics, isfahan university of technology, isfahan, iran

introduction the gamma knife system is designed solely for non-invasive treatment of brain disorders, and it benefits from stereotactic surgical techniques. dose calculations required in the system are performed by gammaplan code; in this code, brain tissue is considered uniform. in the present study, we evaluated the effect of gamma knife system on the obtained dose through simulating a real h...

2017
Wei Lv Hengda He Qian Liu

For evaluating radiation risk, the construction of anthropomorphic computational phantoms with a variety of physiques can help reduce the uncertainty that is due to anatomical variation. In our previous work, three deformable Chinese reference male phantoms with 10th, 50th and 90th percentile body mass indexes and body circumference physiques (DCRM-10, DCRM-50 and DCRM-90) were constructed to r...

Journal: :Journal of biomedical optics 2013
Cuiru Sun Beau Standish Barry Vuong Xiao-Yan Wen Victor Yang

Optical coherence elastography (OCE) provides deformation or material properties, mapping of soft tissue. We aim to develop a robust speckle tracking OCE technique with improved resolution and accuracy. A digital image correlation (DIC)-based OCE technique was developed by combining an advanced DIC algorithm with optical coherence tomography (OCT). System calibration and measurement error evalu...

2017
Om Prakash Gurjar Radha Kishan Paliwal Surendra Prasad Mishra

The aim is to study the density, isodose depths, and doses at different points in slab-pinewood-slab (SPS) phantom, solid phantom SP34 (made up of polystyrene), and chest level of actual patient for developing heterogeneous chest phantom mimicking thoracic region of human body. A 6 MV photon beam of field size of 10 cm × 10 cm was directed perpendicular to the surface of computed tomography (CT...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید