This study intended to optimize the radiation doses for gastroenterologists and patients during therapeutic endoscopic retrograde cholangiopancreatography (ERCP) and to compare the doses based on available data obtained by other researchers. A total of 153 patients were studied in two Gastroenterology Departments, (group A, 111; group B, 42). Thermoluminescent dosimeters (TLD) were used to meas...
Acceptance testing and commission are essential elements of the quality assurance program for imaging equipment. We present results a performance evaluation Flat Panel-Based Cardiovascular Fluoroscopy X-ray Systems as part acceptance commissioning. Measurements were obtained using calibrated dose rate meter, patient equivalent phantoms, Leeds image test tools. The compared with manufacturer Eur...
Purpose. This cross-sectional, observational study used Fourier-domain optical coherence tomography (OCT) to examine the position, patency, and the interior entrance site of anterior chamber (AC) aqueous tube shunts. Methods. The OCT, slitlamp biomicroscopy, and gonioscopy findings of 23 eyes of 18 patients with AC shunts were collected and compared. Results. OCT images demonstrated the shunt p...
Dental Press J Orthod 42 2010 Sept-Oct;15(5):42-3 * Access www.dentalpress.com.br/journal to read the full article. Editor’s summary The voxel size, the smallest unit of a ConeBeam Computed Tomography (CBCT) image, is related to the definition of tomographic image. The question raised by the authors of this study is whether voxel size can affect radiation dose during CT scanning. Measurement of...
Background and purpose: By increasing use of X-ray in medical diagnosis, it is essential to gain awareness on the amount of absorbed dose in patients according to the world standard levels. The aim of this study was to estimate the entrance surface dose (ESD) and effective dose (ED) of the patients in imaging (chest and abdomen) with diagnostic radiology systems in Hamadan, Iran; and comparing ...
PURPOSE To evaluate the neutron and photon dose equivalent rate (H(n,D) and H(G)) at the outer maze entrance and the adjacent treatment console area after the installation of a Varian Clinac 23EX accelerator with a higher beam energy than its predecessor. The evaluation was based on measurements and comparison with several empirical calculations. The effectiveness of borated polyethylene (BPE) ...
PURPOSE The magnetic fields of linac-MR systems modify the path of contaminant electrons in photon beams, which alters patient skin dose. To accurately quantify the magnitude of changes in skin dose, the authors use Monte Carlo calculations that incorporate realistic 3D magnetic field models of longitudinal and transverse linac-MR systems. METHODS Finite element method (FEM) is used to genera...
Objectives. To compare the effectiveness of the bismuth breast shield and partial CT scan in reducing entrance skin dose and to evaluate the effect of the breast shield on image quality (IQ). Methods. Nanodots were placed on an adult anthropomorphic phantom. Standard chest CT, CT with shield, and partial CT were performed. Nanodot readings and effective doses were recorded. 50 patients with che...
Background: The radiation dose received by contralateral breast (CLB) is one of the concerns of breast radiotherapy, because it may lead to the induction of secondary breast cancer. The aim of this study was to evaluate the CLB surface dose in the breast treatment in Yazd radiotherapy center. Materials and Methods: The surface dose of CLB was measured using TLD dosimetry in 50 cancer breast pat...