نتایج جستجو برای: dosimetry

تعداد نتایج: 8115  

2008
Hilary Akpati ChangSeon Kim Bong Kim Tae Park Allen Meek

We have formulated a unified dosimetry index (UDI) that computes, for any given treatment plan, its deviations in terms of dose coverage, conformity, homogeneity, and dose gradient vis-à-vis an ideal plan (which we define as a dosimetry plan of perfect dose coverage, conformity, homogeneity, and step-wise fall-off to zero dose outside the planning target volume). In order to validate the UDI sc...

2012
Takashi Nakamura

Various neutron detectors for spectrometry, environmental dosimetry and personal dosimetry have been developed by our group. For high energy neutron spectrometry, spallation detectors of C and Bi, large plastic and NE-213 scintillators, self TOF detector have been used for neutron production and shielding experiments at several high energy accelerator facilities, ISIS of Rutherford Appleton Lab...

2017
Stefano Peca Richie Siddhartha Sinha Derek Wilson Brown Wendy Lani Smith

PURPOSE We recently developed a novel, open-source in vivo dosimetry that uses the electronic portal imaging device to detect dose delivery discrepancies. We applied our method on patients with rectal cancer treated on a belly board device. METHODS In vivo dosimetry was performed on 10 patients with rectal cancer treated prone on the belly board with a 4-field box arrangement. Portal images w...

Journal: :Journal of biomedical optics 2016
Johannes Swartling Odd V Höglund Kerstin Hansson Fredrik Södersten Johan Axelsson Anne-Sofie Lagerstedt

Online light dosimetry with real-time feedback was applied for temoporfin-mediated interstitial photodynamic therapy (PDT) of dog prostate. The aim was to investigate the performance of online dosimetry by studying the correlation between light dose plans and the tissue response, i.e., extent of induced tissue necrosis and damage to surrounding organs at risk. Light-dose planning software provi...

2008
Parminder Basran Collins Yeboah

A methodology for the dosimetric verification of micro-multileaf collimator MMLC) based intensity modulated radiation therapy (IMRT) plans intended for stereotactic applications is described. The procedure is similar to that of conventional IMRT patient-specific quality assurance with some notable exceptions. Relative dosimetry measurements are performed with radiographic film, a commercial fil...

2014
SM Hosseini Pooya T Orouji

BACKGROUND The accurate results of the individual doses in personal dosimety which are reported by the service providers in personal dosimetry are very important. There are national / international criteria for acceptable dosimetry system performance. Objective : In this research, the sources of uncertainties are identified, measured and calculated in a personal dosimetry system by TLD. METHO...

Journal: :European journal of radiology 2008
Scott D Oves Kenneth R Hogstrom Kyungmin Ham Erno Sajo Joseph P Dugas

The purpose of this study was to compare dose measurements using ion chamber and radiochromic film dosimetry for a 35-keV synchrotron beam useful for Auger electron therapy. A 1.3-GeV electron beam, transported through a 3-pole superconducting wiggler magnet, produced a polychromatic photon beam from which a 35-keV beam (3.3 mm Al HVL) was selected using a monochromator. A 2.8 cm x 2.5 cm field...

2011
Eduardo de Paiva Luiz A. R. da Rosa Ricardo R. A. Brito Lidia V. de Sá Ana C. M. Dovales Delano V. S. Batista Ricardo A. Giannoni Alexandre F. Velasco

The Brazilian Institute of Radiation Protection and Dosimetry (IRD/CNEN) carried out quality assurance regulatory audits in Brazilian radiotherapy facilities from 1995 to 2007. In this work, the set of data collected from 195 radiotherapy facilities that use high-energy photon beams are analyzed. They include results from audits in linear electron accelerators and/or Co-60 units. The inspectors...

2009
M. F. Desrosiers M. Peters J. M. Puhl

The response of high-dose-range chemical dosimeters is dependent on the dosimeter temperature during irradiation. Typically, irradiation temperatures are estimated by measurements, calculations, or some combination of the two. Then using the temperature coefficient for the dosimetry system, the dosimeter response is adjusted or corrected to be consistent with the irradiation temperature for the...

Journal: :Physics in medicine and biology 2014
Robin Hill Brendan Healy Lois Holloway Zdenka Kuncic David Thwaites Clive Baldock

This topical review provides an up-to-date overview of the theoretical and practical aspects of therapeutic kilovoltage x-ray beam dosimetry. Kilovoltage x-ray beams have the property that the maximum dose occurs very close to the surface and thus, they are predominantly used in the treatment of skin cancers but also have applications for the treatment of other cancers. In addition, kilovoltage...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید