نتایج جستجو برای: cbct scan

تعداد نتایج: 84508  

2015
Amin Rahpeyma Saeedeh Khajehahmadi

Open sinus lift surgery is a form of pre-prosthetic surgery for increasing the quality and quantity of bone in the posterior region of the maxilla. Pre-operative assessment of the maxillary sinus is essential for the success of this surgery. PubMed search was carried out in English language literature for open sinus lift surgery and cone-beam computed tomography (CBCT). The results focused on a...

2017
Xiujuan Gai Yumei Wei Hengmin Tao Jian Zhu Baosheng Li

PURPOSE To study the necessity of repeat computed tomography (CT) scan and replanning and know a more accurate time using weekly kilovoltage cone beam computed tomography (kV-CBCT) scans for patients with nasopharyngeal carcinoma (NPC) during radiotherapy. METHODS AND MATERIALS Thirteen NPC patients treated with IMRT were enrolled into this prospective study. Weekly pretreatment kV-CBCT scans...

Journal: :The International journal of oral & maxillofacial implants 2013
Federico Hernández-Alfaro Manuel Sancho-Puchades Raquel Guijarro-Martínez

PURPOSE To perform a preliminary validation with cone beam computed tomography (CBCT) of the combined use of intraoral bone blocks and biomaterials for total reconstruction of the atrophic maxilla. MATERIALS AND METHODS Consecutive cases of total edentulism of the maxilla (Cawood and Howell classes IV or V) treated with bilateral sinus floor elevation, mandibular bone block grafts, and biomat...

2013
Frits A. Rangel Thomas J. J. Maal Ewald M. Bronkhorst K. Hero Breuning Jan G. J. H. Schols Stefaan J. Bergé Anne Marie Kuijpers-Jagtman

Several methods have been proposed to integrate digital models into Cone Beam Computed Tomography scans. Since all these methods have some drawbacks such as radiation exposure, soft tissue deformation and time-consuming digital handling processes, we propose a new method to integrate digital dental casts into Cone Beam Computed Tomography scans. Plaster casts of 10 patients were randomly select...

2013
J BARBER J R SYKES L HOLLOWAY D I THWAITES

The performance of an automatic image registration algorithm was compared on image sets collected with two commercial CBCT systems, and the relationship with imaging dose was explored. CBCT images of a CIRS Virtually Human Male Pelvis phantom (VHMP) were collected on Varian TrueBeam/OBI and Elekta Synergy/XVI linear accelerators, across a range of mAs settings. Each CBCT image was registered 10...

Journal: :Brazilian oral research 2012
José Rino Neto Fernando Penteado Lopes da Silva Israel Chilvarquer João Batista de Paiva Angélica Maria Hernandez

The aim of this study was to determine whether image artifacts caused by orthodontic metal accessories interfere with the accuracy of 3D CBCT model superimposition. A human dry skull was subjected three times to a CBCT scan: at first without orthodontic brackets (T1), then with stainless steel brackets bonded without (T2) and with orthodontic arch wires (T3) inserted into the brackets' slots. T...

2015
Gurudutt Nayak Kamal Krishan Singh Rhitu Shekhar

Variation in root canal morphology, especially in maxillary first molar presents a constant challenge for a clinician in their detection and management. This case report describes the successful root canal treatment of a three rooted right maxillary first molar presenting with three canals each in the mesiobuccal and distobuccal roots and one canal in the palatal root. The clinical detection of...

Journal: :International endodontic journal 2017
S Patel A Aldowaisan A Dawood

AIM This case report describes a new approach to isolation and soft tissue retraction during endodontic surgery using cone-beam computed tomography (CBCT), computer-aided design (CAD) and three-dimensional (3D) printing. SUMMARY A 53-year-old patient presented for endodontic treatment of her maxillary left central incisor. It was decided to treat this tooth with a microsurgical approach. The ...

2016
Woo-Young Lee Young-Wook Park Kwang-Jun Kwon Seong-Gon Kim

BACKGROUND The purpose of this retrospective study was to develop a two- and three-dimensional analysis of the airway using cone-beam computed tomography (CBCT) and to determine whether the airway space would be changed in mandibular prognathism after bimaxillary surgery involving maxillary posterior impaction. METHODS Patients requiring orthognathic surgery from 2012 to 2014 were recruited f...

2010
Clemens Maaß Frank Dennerlein Frédéric Noo Marc Kachelrieß

Purpose: With increasing cone angle the cone– beam artifacts in x–ray CT become more and more prominent. It is well known that cone–beam CT (CBCT) does not satisfy the data completeness condition for exact image reconstruction and therefore allows only for approximate image reconstruction [1]. Additionally, in clinical C–arm CT often only a short scan with less than a full rotation can be acqui...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید