نتایج جستجو برای: arterial oxygen pressure

تعداد نتایج: 678217  

Journal: :British journal of anaesthesia 1970
M K Sykes A P Adams W E Finlay A E Wightman J P Munroe

Changes in cardiorespiratory function resulting from haemorrhage and overtransfusion were measured in forty-seven dogs during controlled ventilation. In the animals bled to a mean arterial pressure of 70 mm Hg there were significant reductions in arterial Pco,, carbon dioxide output and oxygen consumption, cardiac output and total venous admixture. In the animals transfused to a mean central ve...

2016
Bang-Gee Hsu Chung-Jen Lee Yen-Cheng Chen Guan-Jin Ho Teng-Yi Lin Ming-Che Lee

Oxidative stress is a causative mechanism of vascular alterations resulting in arterial stiffness. The aim of this study was to evaluate the relationship between oxidative stress and arterial stiffness among kidney transplantation (KT) patients. Fasting blood samples were obtained from 70 KT patients. Arterial stiffness was measured by brachial-ankle pulse wave velocity. Oxidative stress was me...

Journal: :Journal of cardiology 2001
Y Kashiwagi S Beppu F Ishikura H Ueda S Yagura H Kayano

OBJECTIVES Levovist can opacify the myocardium via venous injection, and is widely used in the clinical field. However, left ventricular opacification deteriorates during oxygen inhalation using Albunex, one of the first generation of contrast agents. This study examines the effect of blood oxygen pressure on the myocardial opacification by Levovist. METHODS Myocardial contrast echocardiograp...

Journal: :The Journal of experimental biology 2004
Suzanne L Munns Lynn K Hartzler Albert F Bennett James W Hicks

The effects of treadmill exercise on components of the cardiovascular (venous return, heart rate, arterial blood pressure) and respiratory systems (minute ventilation, tidal volume, breathing frequency, oxygen consumption, carbon dioxide production) and intra-abdominal pressure were investigated in the Savannah monitor lizard, Varanus exanthematicus B., at 35 degrees C. Compared with resting co...

Journal: :BMJ 1989
M Singer D Bennett

OBJECTIVE To assess oesophageal Doppler ultrasonography as a convenient means of optimising positive end expiratory pressure for maximal delivery of oxygen to tissues. DESIGN Measurements of blood flow, arterial oxygen saturation, and cardiac output by thermodilution (when available) at baseline and at 20-30 minutes after each incremental increase (2.5-5.0 cm H2O) in positive and expiratory p...

2014
Alireza Sharifian Attar Masoomeh Tabari Mohammadreza Rahnamazadeh Maryam Salehi

BACKGROUND Hypoxia occurs during one-lung ventilation (OLV) due to the arteriovenous shunt of unsaturated pulmonary venous blood. Hypoxic pulmonary vasoconstriction (HPV) acts as a defense mechanism against shunting. In thoracic surgery, anesthetics with minimal inhibitory effect on HPV and minimal hemodynamic changes are preferred. OBJECTIVES The present study aimed to evaluate the effects o...

Journal: :American journal of physiology. Heart and circulatory physiology 2000
S M Santilli A S Tretinyak E S Lee

Intimal hyperplasia, common at the deployment site of an intra-arterial stent, may be caused by artery wall hypoxia. The purpose of this study was to determine the effect of an intra-arterial stent on artery wall oxygen concentrations. Transarterial wall oxygen gradients were measured by microelectrode at stent deployment sites in New Zealand White rabbits. Thinned artery walls and decreased ox...

Journal: :Canadian Anaesthetists' Society journal 1979
A Fargas-Babjak J B Forrest

The pulmonary vascular response to alveolar hypoxia with and without halothane exposure was measured in dogs. Hypoxia increased pulmonary artery pressure (Ppa) and pulmonary vascular resistance (PVR) so that in each case inverse linear relationships were found with arterial oxygen saturation. These responses were highly significant and reproduceable but varied greatly between individuals. Halot...

Journal: :Circulation 1966
N Banchero F Sime D Peñaloza J Cruz R Gamboa E Marticorena

The response elicited by exercise on pulmonary pressure, cardiac output, and arterial oxygen saturation in 35 lifetime residents of high altitude has been studied at high altitude (14,900 feet above sea level), and 22 residents of low altitude have been studied at sea level. A procedure combining cardiac catheterization, arterial cannulation, and spirometry was carried out. The exercise was mod...

Journal: :acta medica iranica 0
d. attaran m. towhidi m. amini m. toosi

a significant reduction in arterial blood oxygen saturation during fiberoptic bronchoscopy has been proved but it is not yet known whether all patients need supplemental oxygen during this procedure. the aim of study is to examine the relationship between peak expiratory flow rate (pefr) before bronchoscopy and oxygen desaturation during bronchoscopy. measurement of pefr (% predicted) performed...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید