S everal radial artery anatomic variations have been described (1,2). These are especially important for the radialists in the catheterization laboratory for troubleshooting, especially with the growing popularity of the radial artery as the preferred access site for diagnostic and interventional coronary angiographic procedures. Variation in the origin of the radial artery is a common anomaly ...
OBJECTIVE Our aim was to study the significance of persistently absent radial pulse, with monophasic doppler flow after close reduction percutaneous pinning of displaced supracondylar fracture of humerus, and the need of early exploration of brachial artery in such cases. METHODS Between July 1992 and 1999, 86 children with Grade III supracondylar fracture of humerus were treated at King Khal...
Instruction: Measurement of brachial artery diameter variation by ultrasound methods has commonly been used to test the endothelial function. It is known that the artery diameter is increased by flow stimulation. Therefore in the present study, the effect of external obstruction, as flow stimulation, on the radial strain of the brachial artery was assessed. Also the biomechanical behavior of th...
Variations in the arterial pattern of the upper limb are very common as observed in many cadaveric and angiographic studies. Knowledge of variations in the origin and course of the radial artery is important because they are used for many diagnostic procedures as well as vascular and reconstructive surgeries like coronary angiography, percutaneous coronary intervention and coronary artery bypas...
Peripheral artery cannulation is a common procedure but can sometimes be difficult. Our goal was to determine if a median nerve block would increase the diameter and flow of the radial artery. Radial artery diameter and peak velocity was measured using a SonoSite Ultrasound System. Using ultrasound guidance, a median nerve block was performed with lidocaine. Subsequent measurements of the radia...
Use of the radial artery for cardiac catheterization has significantly reduced the incidence and severity of complications at the access site. Nevertheless, occasionally unusual complications or atypical responses to treatment are observed. We describe two cases: a radial artery pseudoaneurysm that was unresponsive to compression treatment and a foreign-body inflammatory reaction at the radial ...
patients are asymptomatic.1 The syndrome of subclavian steal caused by an occlusive lesion of the aberrant subclavian artery is a rare clinical finding.1-4 This syndrome results from the abnormal flow of blood due to the occlusion in the subclavian artery proximal to the origin of the vertebral artery. Blood flow through the vertebral artery is consequently reversed and the subclavian one thus ...
BACKGROUND Blood pressure (BP) monitoring with arterial waveform display requires an arterial cannula. We evaluated a new noninvasive device, Vasotrac (Medwave, Arden Hills, MN) that provides BP measurements approximately every 12-15 beats and displays pulse rate and a calibrated arterial waveform for each BP measurement. METHODS Surgical and critically ill patients (n = 80) served as subject...