نتایج جستجو برای: تصویربرداری spect

تعداد نتایج: 13075  

Journal: :Circulation journal : official journal of the Japanese Circulation Society 2002
Naoko Yasugi Samon Koyanagi Keizaburo Ohzono Kikuo Sakai Takahiro Matsumoto Shigeki Sako Tomoki Homma Shirou Azakami Tadayuki Hiroki

Discordance between the (123)I-labelled 15-iodophenyl-3-R, S-methyl pentadecanoic acid (BMIPP) and (201)Tl findings may indicate myocardial viability (MV). This study compared dobutamine stress echocardiography (DSE) and single-photon emission computed tomography (SPECT) using the dual tracers for assessment of MV and prediction of functional recovery after acute myocardial infarction (AMI). DS...

1998

Multimodality visualization aims at efficiently presenting integrated information obtained from different modalities, usually combining a functional modality (SPECT, PET, fMRI) with an anatomical modality (CT, MRI). This chapter presents a technique for 3D integrated visualization of SPECT and MR brain images, where MRI is used as a framework of reference for the display of the SPECT data. Meth...

Journal: :Magnetic resonance imaging 1999
T Ernst L Chang L Itti O Speck

The objective of this study was to determine the relationship in regional cerebral blood flow (rCBF) as measured with perfusion magnetic resonance imaging (pMRI) and single photon emission computer tomography (SPECT). rCBF was determined in 26 healthy subjects with pMRI and SPECT. After co-registration of pMRI with SPECT, rCBF was determined in 10 brain regions relative to the whole slice value...

2011
Mark Jason Hamamura Seunghoon Ha Werner W Roeck James Hugg Dirk Meier Bradley E Patt Orhan Nalcioglu

Purpose MRI and single-photon emission computed tomography (SPECT) provide complimentary information which could aid in the diagnosis of various diseases. However, acquiring images from both modalities can been problematic. Until recently, SPECT systems could not be integrated with MRI systems due to the use of photomultiplier tubes which do not function in high magnetic fields. The development...

2008
M. J. Hamamura S. H. Ha W. W. Roeck O. Nalcioglu D. J. Wagenaar D. Meier B. E. Patt

Purpose: We had previously shown the MR compatibility of CZT based single photon detectors and associated nuclear data acquisition electronics [1]. The purpose of the present work was to study the feasibility a combined MRSPECT system operating inside a 4T MR system for dual-modality MR-SPECT imaging. The current investigation included a study of the effect of SPECT detector/collimator system o...

2015
Takeshi Murakami Jun Hashimoto Taeko Hara Takashi Yamashita Toshiki Kazama Yutaka Imai

Background: Real cardiac phantoms are often used to assess the performance of software for gated single-photon emission computed tomography(SPECT). However, these phantoms have disadvantages in that they are not very similar to actual hearts and setting a perfusion defect is not easy. To overcome these problems, we developed a digital myocardial phantom, named%Myo-Simu'. The aims of this study ...

Journal: :The Australian and New Zealand journal of psychiatry 2001
J Garcia-Campayo C Sanz-Carrillo T Baringo C Ceballos

OBJECTIVE There are no previous studies using single photon emission computed tomography (SPECT) scans in somatization disorder (SD) patients. The aim of this paper is to assess SPECT imaging abnormalities in SD patients and study any relation to laterality. METHOD Eleven SD patients from the Somatization Disorder Unit of Miguel Servet University Hospital, Zaragoza, Spain, not fulfilling crit...

Journal: :American heart journal 2006
Bhavani Balaravi Todd D Miller David O Hodge Raymond J Gibbons

BACKGROUND Dyspnea is a complex system with multiple etiologies, including myocardial ischemia ("anginal equivalent"). Few studies have examined the utility of stress testing to detect coronary artery disease in this setting. The purpose of this study was to examine the prevalence, severity, and prognostic value of perfusion defects detected by stress single photon emission computed tomography ...

Journal: :Revista espanola de cardiologia 2013
Gemma Cuberas-Borrós Victor Pineda Santiago Aguadé-Bruix Guillermo Romero-Farina M Nazarena Pizzi Gustavo de León Joan Castell-Conesa David García-Dorado Jaume Candell-Riera

INTRODUCTION AND OBJECTIVES The aim of this study was to compare magnetic resonance and gated-SPECT myocardial perfusion imaging in patients with chronic myocardial infarction. METHODS Magnetic resonance imaging and gated-SPECT were performed in 104 patients (mean age, 61 [12] years; 87.5% male) with a previous infarction. Left ventricular volumes and ejection fraction and classic late gadoli...

Journal: :European heart journal cardiovascular Imaging 2014
Hack-Lyoung Kim Yong-Jin Kim Seung-Pyo Lee Eun-Ah Park Jin-Chul Paeng Hyung-Kwan Kim Whal Lee Goo-Yeong Cho Joo-Hee Zo Dong-Ju Choi Dae-Won Sohn

AIMS This study was conducted to investigate the incremental prognostic value of sequential use of single-photon emission computed tomography (SPECT) and coronary computed tomography angiography (CCTA) in patients with suspected coronary artery disease (CAD). METHODS AND RESULTS A total of 1295 patients with suspected CAD who underwent both CCTA and SPECT within 90 days was retrospectively re...

نمودار تعداد نتایج جستجو در هر سال