نتایج جستجو برای: titanium sheet

تعداد نتایج: 74959  

Journal: :JOM 2021

Abstract The “stress-shielding” problem, common with metallic implants, may be solved by using biocompatible sandwiches a polymeric core between two skin sheets. To achieve such sandwiches, process route has been developed, beginning the grafting of poly-(methyl-methacrylate) (PMMA) on titanium (Ti) sheets via “grafting from” technique. Grafting resulted in variable thicknesses PMMA Ti Hot-pres...

Journal: :Water science and technology : a journal of the International Association on Water Pollution Research 2009
Y Okour H K Shon I El Saliby

Flocculation with titanium tetrachloride (TiCl(4)) and titanium sulfate (Ti(SO(4))(2)) was investigated in terms of different coagulant doses, pH, turbidity, dissolved organic carbon (DOC), UV-254, colour, zeta potential, particle size and molecular weight distribution. The two coagulants were compared with the commonly used coagulants such as ferric chloride (FeCl(3)) and aluminium sulfate (Al...

Journal: :International journal of nanomedicine 2016
Makiko Saita Takayuki Ikeda Masahiro Yamada Katsuhiko Kimoto Masaichi Chang-Il Lee Takahiro Ogawa

BACKGROUND Although biomimetic apatite coating is a promising way to provide titanium with osteoconductivity, the efficiency and quality of deposition is often poor. Most titanium implants have microscale surface morphology, and an addition of nanoscale features while preserving the micromorphology may provide further biological benefit. Here, we examined the effect of ultraviolet (UV) light tr...

2017
Chengbao Xu Yimin Zhang Tao Liu Jing Huang

A large number of unexploited low-grade vanadium-titanium magnetite deposits have been found in the Chao-yang area of China in recent years. The reserves are estimated at more than 20 billion tons. A mineralogical study of raw sample indicated that it was a typical low-grade vanadium-titanium magnetite ore with weathering. Most of vanadium-titanium magnetite was replaced by martite and sphene, ...

2015
P. Santiago-Medina P. A. Sundaram N. Diffoot-Carlo

Titanium and titanium alloys are currently accepted as the gold standard in dental applications. Their excellent biocompatibility has been attributed to the inert titanium surface through the formation of a thin native oxide which has been correlated to the excellent corrosion resistance of this material in body fluids. Whether this titanium oxide layer is essential to the outstanding biocompat...

Journal: :International Journal of Nanomedicine 2008
George E Aninwene Chang Yao Thomas J Webster

Current orthopedic implants have functional lifetimes of only 10-15 years due to a variety of reasons including infection, extensive inflammation, and overall poor osseointegration (or a lack of prolonged bonding of the implant to juxtaposed bone). To improve properties of titanium for orthopedic applications, this study anodized and subsequently coated titanium with drugs known to reduce infec...

Journal: :Kokubyo Gakkai zasshi. The Journal of the Stomatological Society, Japan 2007
Koki Nakajima

Recently, allergy to titanium has been reported. However, the patch test reagent for titanium is not standardized yet. The form and density of the patch test reagent for titanium was changed and examined in a group of normal subjects and a group with skin disease. The following conclusions were obtained. 1. A reagent which was composed of pure titanium powder and vaseline was not preferable bec...

2003
Mitsuo Niinomi

Nb, Ta and Zr are the favorable non-toxic alloying elements for titanium alloys for biomedical applications. Low rigidity titanium alloys composed of non-toxic elements are getting much attention. The advantage of low rigidity titanium alloy for the healing of bone fracture and the remodeling of bone is successfully proved by fracture model made in tibia of rabbit. Ni-free super elastic and sha...

Journal: :شیمی کاربردی 0
سید حسن زوار موسوی hasan zavar mousavi ناهید پوررضا nahid pourreza

a simple, selective and sensitive method for the determination of trace amount of titanium (iv) based on its catalytic effect on methylene blue- ascorbic acid redox reaction has been reported. the reaction was followed spectrophotometrically by measuring the change in absorbance of methylene blue at 665 nm, 5 minutes after the initiation of the reaction. in this study experimental parameters we...

Journal: :iranian journal of analytical chemistry 2014
nagaraj p shetty gopalakrishna bhatn chandrashekara kg

a complexometric method for the determination of titanium in the presence of other metal ions based on the selective masking ability of 5-sulphosalicylic acid towards titanium is described. titanium (iv) present in a given sample solution is complexed with a known excess of edta and surplus edta is titrated against zinc sulphate solution at ph 5-6 using xylenol orange as the indicator. a known ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید