نتایج جستجو برای: tidal volume
تعداد نتایج: 334062 فیلتر نتایج به سال:
Effect of pressure application by a crutch to the axilla of the side of the dominant right nostril on the pattern of nostril dominance with emphasis on the time sequence of changes and recovery was studied in the young male Nigerians. The nostril dominance was assessed from the percentage of tidal volume flowing through the right and left nostril passages during expiratory phase (7). Applicatio...
Protective ventilation with low tidal volume has been shown to reduce morbidity and mortality in patients suffering from acute lung injury (ALI) and acute respiratory distress syndrome (ARDS). Low tidal volume ventilation is associated with particular clinical challenges and is therefore often underutilized as a therapeutic option in clinical practice. Despite some potential difficulties, data ...
Minute ventilation (VE) (ml min-1), respiratory frequency (f), mixed expired carbon dioxide fraction (FECO2) and end-tidal carbon dioxide concentration (E'CO2) (%) were measured, and alveolar ventilation (VA), deadspace (VD), deadspace/tidal volume ratio (VD/VT) and carbon dioxide output (VCO2) calculated in 58 anaesthetized, spontaneously breathing infants and children weighing 2.8-20.5 kg. Al...
so the CO2 tension can be measured in a gas rather than in a liquid (Campbell and Howell, 1960a). The problem is to achieve this equilibrium before the prevention of its excretion causes the pressure of the CO2 in the blood to rise excessively. A rapid equilibrium will be achieved if a gas mixture is rebreathed which contains enough CO2 to enrich the alveolar gas to approximately the same tensi...
The effect of raising the airways resistance of 56 normal newborn babies by blocking alternate nostrils was studied by means of oesophageal intubation and the trunk plethysmograph. Increased resistance was associated with reduced respiratory rate and ventilation. A comparison was made of the response in different sleep states. In rapid eye movement (REM) sleep respiratory tidal volume decreased...
Ideally, the inspired (tidal) volume (V(T)) provided by a volume-controlled ventilation device should not change when the pressure imposed on the ventilator varies. A bench study evaluation of V(T) versus pressure was performed on 10 commercially available devices. The difference between the desired V(T) and the observed V(T) reached 100 mL for some devices when inspiratory resistance was at it...
In this paper the use of a continuous-wave microwave sensor as a non-contact tool for quantitative measurement of respiratory tidal volume has been evaluated by experimentation in seventeen healthy volunteers. The sensor working principle is reported and several causes that can affect its response are analyzed. A suitable data processing has been devised able to reject the majority of breath me...
MOTIVATION: In lung EIT, the quantity of interest is the change in regional air volume in the lungs. However, the actual quantity reconstructed is change in a bulk electrical property, usually conductivity, which is not always easy to interpret. In this study, we investigate how the choice of the reconstructed physical quantity affects the properties of the sensitivity matrix and images obtaine...
Tidal breathing analysis and response to salbutamol in awake young children with and without asthma.
The purpose of the present study was to investigate: 1) whether tidal flow patterns can be used to discriminate between children with asthma and those without respiratory illness; and 2) whether reversibility to salbutamol in young children can be detected by tidal breathing analysis? Lung function was measured by tidal flow-volume loops (SensorMedics 2600) in 26 awake young children (13 males)...
We assessed the time course of changes in eupneic arterial PCO(2) (Pa(CO(2))) and the ventilatory response to hyperoxic rebreathing after removal of the carotid bodies (CBX) in awake female dogs. Elimination of the ventilatory response to bolus intravenous injections of NaCN was used to confirm CBX status on each day of data collection. Relative to eupneic control (Pa(CO(2)) = 40 +/- 3 Torr), a...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید