نتایج جستجو برای: stroke volume sv

تعداد نتایج: 441500  

Journal: :Japanese heart journal 1998
K Saito M Matsushita A Matsuo

We studied the effects of vigorous rowing training on left ventricular structure and function using M-mode, two-dimensional and Doppler echocardiography in 10 female college rowers. Echocardiographic measurements were performed before and after 20 weeks of rowing training. Diastolic function was also estimated by measuring the isovolumetric relaxation time (IRT), deceleration time (DcT), peak v...

Journal: :International journal of clinical and experimental medicine 2014
Shun-Juan Chen Zhu Gong Qiang-Lin Duan

UNLABELLED To evaluate the capability of impedance cardiography (ICG) in reflecting the cardiac functions of acute myocardial infarction (AMI) patients. METHODS 99 inpatients with initial AMI were recruited. Venous blood was obtained for detection of N-terminal brain-type natriuretic peptide (NT-proBNP), B-Type natriuretic peptide (BNP) and c troponin-T (cTnT) followed by ICG. Thorax fluid ca...

Journal: :The Journal of experimental biology 1988
D L Evans R J Rose

Six detrained Thoroughbred horses performed incremental treadmill tests. Maximal oxygen uptake (VO2max) was measured during exercise by analysis of expired gas. The relationships between oxygen consumption (VO2) and work rate, heart rate (HR), cardiac output (Q), stroke volume (SV) and arteriovenous oxygen content difference [C(a-v)O2] were examined during submaximal and maximal exercise. The r...

2012
Véronique L. Billat Hélène Petot Morgan Landrain Renaud Meilland Jean Pierre Koralsztein Laurence Mille-Hamard

PURPOSE Despite the increasing popularity of marathon running, there are no data on the responses of stroke volume (SV) and cardiac output (CO) to exercise in this context. We sought to establish whether marathon performance is associated with the ability to sustain high fractional use of maximal SV and CO (i.e, cardiac endurance) and/or CO, per meter (i.e., cardiac cost). METHODS We measured...

Journal: :Journal of applied physiology 2008
Kathy L Ryan William H Cooke Caroline A Rickards Keith G Lurie Victor A Convertino

Inspiratory resistance induced by breathing through an impedance threshold device (ITD) reduces intrathoracic pressure and increases stroke volume (SV) in supine normovolemic humans. We hypothesized that breathing through an ITD would also be associated with a protection of SV and a subsequent increase in the tolerance to progressive central hypovolemia. Eight volunteers (5 men, 3 women) were i...

2016
Frédéric Lador Aurélien Bringard Samir Bengueddache Guido Ferretti Karim Bendjelid Paola M Soccal Stéphane Noble Maurice Beghetti Denis Chemla Philippe Hervé Olivier Sitbon

Purpose. Cardiac output (CO) is a cornerstone parameter in precapillary pulmonary hypertension (PH). The Modelflow (MF) method offers a reliable noninvasive determination of its beat-by-beat changes. So MF allows exploration of CO adjustment with the best temporal resolution. Methods. Fifteen subjects (5 PH patients, 10 healthy controls) performed a submaximal supine exercise on a cycle ergomet...

Journal: :American journal of physiology. Heart and circulatory physiology 2002
Frank Weidemann Fadi Jamal George R Sutherland Piet Claus Miroslaw Kowalski Liv Hatle Ivan De Scheerder Bart Bijnens Frank E Rademakers

For porcine myocardium, ultrasonic regional deformation parameters, systolic strain (epsilon(sys)) and peak systolic strain rate (SR(sys)), were compared with stroke volume (SV) and contractility [contractility index (CI)] measured as the ratio of end-systolic strain to end-systolic wall stress. Heart rate (HR) and contractility were varied by atrial pacing (AP = 120-180 beats/min, n = 7), incr...

2017
R. A. Phillips B. E. Smith V. M. Madigan

Purpose of Review Adequate oxygen delivery is essential for life, with hypoxia resulting in dysfunction, and ultimately death, of the cells, organs and organism. Blood flow delivers the oxygen bound in the blood, while haemodynamics is the science of blood flow. Stroke volume (SV) is the fundamental unit of blood flow, and reflects the interdependent performance of the heart, the vessels and th...

2011
Genevieve C. Digby Helen S. Driver Michael Fitzpatrick Glorianne Ropchan Christopher M. Parker

BACKGROUND Attempts to investigate the mechanisms by which continuous positive airway pressure (CPAP) therapy improves heart function in patients with obstructive sleep apnea (OSA) have been limited by the lack of non-invasive methods to assess cardiac performance. We used transthoracic electrical bioimpedance (TEB) to assess acute hemodynamic changes including heart rate (HR), stroke volume (S...

Journal: :Physiological research 2015
P Horn P Ostadal B Ostadal

Exercise stimulates increases in heart rate (HR), stroke volume (SV) and cardiac output (CO). These adaptive mechanisms are strongly dependent on the type of exercise. Both rowing and cycling are widely used for physical training worldwide; however, evidence regarding the differences in major hemodynamic parameters during rowing and cycling remains insufficient. Ten healthy male volunteers were...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید