نتایج جستجو برای: scatter collimator factor

تعداد نتایج: 857363  

Ahmad Mostaar, Ghazale Graily Seied Rabi Mahdavi, Seyed Aliasghar Rohani

  Introduction:    Multileaf collimators (MLCs) are computer-controlled devices which are Useful and cost-effective tools for conformal therapy and intensity modulation radiotherapy (IMRT). Nowadays MLCs are important and standard configuration of the new medical linear accelerators which are substitute of conventional Blocks and has eliminated the ...

Journal: :Medical physics 2001
J H Siewerdsen D A Jaffray

A system for cone-beam computed tomography (CBCT) based on a flat-panel imager (FPI) is used to examine the magnitude and effects of x-ray scatter in FPI-CBCT volume reconstructions. The system is being developed for application in image-guided therapies and has previously demonstrated spatial resolution and soft-tissue visibility comparable or superior to a conventional CT scanner under condit...

Journal: :Journal of radiation research 2001
M Ishikawa T Kobayashi Y Sakurai K Kanda

Because background radiation in an irradiation room creates a problem with the PG-SPECT (Prompt Gamma-ray Single Photon Emission Computed Tomography) system, which evaluates the absorbed dose for the Boron Neutron Capture Therapy treatment, optimization of a collimator system was performed while taking the shielding of background gamma-rays into consideration. Assuming that a parallel-beam coll...

2018
Georg A. Weidlich M. Bret Schneider John R. Adler

Introduction The ZAP-X is a novel self-contained and first-of-its-kind self-shielded therapeutic radiation device dedicated to brain and head and neck radiosurgery. By utilizing a 2.7-MV linear accelerator and incorporating a design in which a beam stop and major mechanical elements serve a radiation shielding function, the Zap-X does not typically require a radiation bunker. The unique collima...

Journal: :Physics in medicine and biology 2015
M Gören Z C Taşkin

Collimator systems used in Intensity Modulated Radiation Therapy can form different geometric aperture shapes depending on their physical capabilities. We compare the efficiency of using regular, rotating and dual multileaf collimator (MLC) systems under different combinations of consecutiveness, interdigitation and rectangular constraints. We also create a virtual freeform collimator, which ca...

Journal: :Computer and Information Science 2011
Xuemei Bai Bin Guo Zhiyong An

As for the optical measurement, the longer the focal length of collimator is, the less the measurement error is. However, the longer the focal length is, the more difficult the optical design is. It's higher application value to design long focal length collimator with wide-view. The paper designs a collimator with 2000mm focal length, 4 degree field of view and its wavelength range is from 480...

2005
Jui-che Tsai

A 1xN2 wavelength-selective switch is demonstrated using a high fill-factor two-axis analog micromirror array and a monolithic 2D collimator array. A 1x2 (scalable to 1x14) WSS with SO-GHz channel spacing is experimentally demonstrated. 02004 Optical Society of America OCIS rodeo: (06C.1810) Couplers, switches, and multiplexers (OM.4510) Optical communications

Journal: :Clinical nuclear medicine 2013
Hiroto Yoneyama

PURPOSE The use of the low-energy high-resolution (LEHR) collimator for lymphoscintigraphy causes the appearance of star-shaped artifacts at injection sites. The aim of this study was to confirm whether the lower resolution of the low- to medium-energy general-purpose (LMEGP) collimator is compensated by decrease in the degree of septal penetration and the reduction in star-shaped artifacts. ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید