نتایج جستجو برای: reciproc file rotary system

تعداد نتایج: 2269593  

Journal: :journal of dentistry, tehran university of medical sciences 0
mohsen aminsobhani naghmeh meraji ehsan sadri

objectives: the purpose of this study was to evaluate the resistance to fatigue failure of five different nickel-titanium rotary files in three different curved trajectories. materials and methods: a total of 150 neoniti a1, race 25.06, mtwo 25.06, twisted file 25.06 and protaper next x2 files with the tip size of 25 were tested (n=30 for each group). three groove types simulating curved canals...

Journal: :iranian endodontic journal 0
fatemeh ramezanali farzaneh afkhami ali soleimani mohammad javad kharrazifard farshid rafiee

introduction: pulpectomy is the preferred treatment for restorable primary teeth with symptomatic irreversible pulpitis or periradicular lesion. considering the rather new application of rotary files for pulpectomy of primary teeth, the aim of this study was to compare the cleaning efficacy and instrumentation time of hand k-files and mtwo rotary system for preparation of human primary molars. ...

Journal: :Iranian endodontic journal 2016
Marcelo Santos Coelho Carlos Eduardo Fontana Augusto Shoji Kato Alexandre Sigrist de Martin Carlos Eduardo da Silveira Bueno

INTRODUCTION The aim of this in vitro study was to evaluate the effects of establishing glide path on the centering ability and preparation time of two single-file reciprocating systems in mesial root canals of mandibular molars. METHODS AND MATERIALS Sixty extracted mandibular molars with curvatures of 25-39 degrees and separate foramina for the mesiobuccal and mesiolingual canals, were divi...

Journal: :Compendium of continuing education in dentistry 2013
James K Bahcall

Of all the procedural problems that can occur when practicing dentistry, endodontic file breakage is one dilemma that not only can lead to extreme stress for the clinician, but can cause great anxiety for the patient as well. Separated rotary nickel-titanium (NiTi) files can also pose an increased risk of post-endodontic complications. Understanding why and how endodontic file breakage occurs, ...

2010
Azza A Dafalla Neamat Hassan Abubakr Yahia E Ibrahim

INTRODUCTION The aim of the present study was to compare hand stainless steel K-files and Nickel-Titanium Profile 0.04 taper 29 series rotary instruments for their efficiency, procedural errors and time consumed in preparation of root canal system. MATERIALS AND METHODS A total of 46 maxillary and mandibular first premolars extracted for orthodontic purposes were collected (two contralateral ...

Journal: :Journal of endodontics 2011
Frank Paqué Matthias Zehnder Gustavo De-Deus

INTRODUCTION A preparation technique with only 1 single instrument was proposed on the basis of the reciprocating movement of the F2 ProTaper instrument. The present study was designed to quantitatively assess canal preparation outcomes achieved by this technique. METHODS Twenty-five extracted human mandibular first molars with 2 separate mesial root canals were selected. Canals were randomly...

2014
Kiamars Honardar Hadi Assadian Shahriar Shahab Zahra Jafari Ali Kazemi Kiumars Nazarimoghaddam Mohammad Javad Kharrazifard Hossein Labbaf

OBJECTIVE Use of rotary Nickel-Titanium (NiTi) instruments for endodontic preparation has introduced a new era in endodontic practice, but this issue has undergone dramatic modifications in order to achieve improved shaping abilities. Cone-beam computed tomography (CBCT) has made it possible to accurately evaluate geometrical changes following canal preparation. This study was carried out to co...

Journal: :Journal of endodontics 2012
Oguz Yoldas Sehnaz Yilmaz Gokhan Atakan Cihan Kuden Zeynep Kasan

INTRODUCTION The purpose of this study was to compare dentinal microcrack formation while using hand files (HFs), 4 brands of nickel-titanium (NiTi) rotary files and the self-adjusting file. METHODS One hundred forty mandibular first molars were selected: 20 teeth were left unprepared and served as control, and the remaining 120 teeth were divided into 6 groups. HFs, HERO Shaper (HS; Micro-Me...

Journal: :journal of dentistry, tehran university of medical sciences 0
mohamad kashefinejad assisstant professor, dental material research center, faculty of dentistry, babol university of medical sciences, babol, iran; department of endodontics, faculty of dentistry, babol university of medical sciences, babol, iran azade harandi assisstant professor, dental material research center, faculty of dentistry, babol university of medical sciences, babol, iran; department of endodontics, faculty of dentistry, babol university of medical sciences, babol, iran saeed eram student research committee, babol university of medical sciences ali bijani social determinants of health research center, health research institute, babol university of medical sciences, babol, iran

objectives: pain is an unpleasant outcome of endodontic treatment that can be unbearable to patients. instrumentation techniques may affect the frequency and intensity of post-endodontic pain. this study aimed to compare single visit post endodontic pain using mtwo (niti) rotary and hand k-file instruments. materials and methods: in this randomized controlled trial, 60 teeth with symptomatic ir...

Journal: :Journal of endodontics 2011
Marco Aurélio Versiani Jesus Djalma Pécora Manoel Damião de Sousa-Neto

INTRODUCTION The aim of this study was to evaluate the root canal preparation in flat-oval canals treated with either rotary or self-adjusting file (SAF) by using micro-tomography analysis. METHODS Forty mandibular incisors were scanned before and after root canal instrumentation with rotary instruments (n = 20) or SAF (n = 20). Changes in canal volume, surface area, and cross-sectional geome...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید