نتایج جستجو برای: pvc based membrane
تعداد نتایج: 3283838 فیلتر نتایج به سال:
Novel miniaturized polyvinyl chloride (PVC) membrane sensors in all-solid state graphite and platinum wire supports were developed, electrochemically evaluated and used for the assay of rivastigmine hydrogen tartrate drug (RIV). The RIV sensors are based on the formation of an ion-association complex between the drug cation and tetrakis(4-chlorophenyl)borate (TpClPB) anionic exchanger as electr...
A novel poly(vinyl chloride) (PVC) membrane electrode based on naphto-9-crown-3 was prepared and tested for the selective detection of beryllium ions. A suitable lipophilicity of the carrier and appropriate coordination ability were found to be essential for designing an electrode with good response characteristics. A PVC membrane with 9% naphtho-9-crown-3 carrier, 58% o-NPOE plasticizer, 3% te...
Four clones of murine leukemia viruses (PVC-111, PVC-211, PVC-321, and PVC-441) were isolated from a paralyzed Fischer rat which had been infected with rat-passaged Friend leukemia virus. PVC-211 and PVC-321 viruses induced hind leg paralysis in rats and killed them within 1 month, and PVC-441 did so within 2 months after infection, whereas PVC-111 did not within 4 months. PVC-321 and PVC-441 b...
The construction and general performance characteristics of two novelpotentiometric membrane sensors responsive to the acebutolol are described. Thesensors are based on the use of ion-association complexes of acebutolol (AC) withtetraphenylborate(TPB) (I) and phosphomolybdate(PM) (II) as exchange sites in a PVCmatrix. The sensors show a fast, stable and near- Nernstian for the mono charge catio...
Lead-based stabilisers, such as lead sulphate and lead stearate, currently used in the processing of polyvinylchloride (PVC) products are being substituted with more environmentally safe, economically viable and higher quality materials. This study aimed to use hydrotalcites (HTs), which are environmentally non-hazardous and simple to synthesise, to effectively quench the HCl gas evolved during...
A PVC ion-selective membrane electrode based on Cd-tetraphenyl porphyrine as a carrier was prepared fordetermination of MnO4- ion. This electrode revealed good selectivity toward permanganate ion over a widevariety of anions. Effects of some experimental parameters such as nature of the plasticizer, the amounts ofcarrier and additive, and concentration of the internal solution on the potential ...
A new polyvinyl choloride (PVC) membrane sensor for cerium (III) was prepared based on 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane (kryptofix22DD) as an ionophore. The sensor exhibites a linear concentration range of 1.0×10-6to 1.0×10-1M, with a Nernstian slope of 18.0±1.0 mV/decade, and a detection limit of 9.7×10-7M. It has a fast response time (5 s) and can be used for two mont...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید