نتایج جستجو برای: prosthesis loosening

تعداد نتایج: 31838  

Journal: :The Journal of bone and joint surgery. British volume 2009
A Terrier F Merlini D P Pioletti A Farron

Wear of polyethylene is associated with aseptic loosening of orthopaedic implants and has been observed in hip and knee prostheses and anatomical implants for the shoulder. The reversed shoulder prostheses have not been assessed as yet. We investigated the volumetric polyethylene wear of the reversed and anatomical Aequalis shoulder prostheses using a mathematical musculoskeletal model. Movemen...

Journal: :The Journal of bone and joint surgery. British volume 1978
C G Attenborough

The stabilised gliding knee prosthesis is a compromise between hinged joints and condylar prostheses. It is a two-piece implant designed to allow normal gliding movements of flexion and extension and which, stabilised by a connecting rod between the femoral and tibial components, allows a designed laxity of rotation and lateral movements. A modification of the original femoral component is desc...

2007
F. Lam D. N. Bhatia S. B. Mostofi K. van Rooyen J. F. de Beer

ont matter & 2006 006.10.004 thor. [email protected] Summary The treatment of combined glenohumeral arthritis and massive rotator cuff deficiency remains a unique challenge. Prosthetic reconstruction is aimed at restoring the normal kinematics of the glenohumeral joint. The reverse shoulder prosthesis medialises the centre of rotation of the glenohumeral joint, thereby lengthening the deltoid lev...

2011
Antonio Spinarelli Vittorio Patella Vito Conserva Giovanni Vicenti Vito Pesce Silvio Patella

Painful hip prosthesis is the most feared immediate and remote complication of a primary implant and usually represents the failure of one or more therapeutic moments. In cases of aseptic implant failure, the causes invoked may be represented by an incorrect indication, the quality of materials, local and general condition of the patient and especially from a bad joint biomechanics. In cases of...

Journal: :The Journal of bone and joint surgery. British volume 2003
H J Kooijman A P P M Driessen J R van Horn

We studied retrospectively the outcome of patellofemoral arthroplasty (PFA) using the Richards prosthesis in 51 patients (56 knees). Their mean age was 50 years (30 to 77). In 43 patients (45 knees), the American Knee Society score and the patients' subjective judgement were assessed. Excellent or good results were obtained in 86% of cases at a mean follow-up of 17 years (15 to 21). Because of ...

Journal: :The Journal of bone and joint surgery. British volume 1991
B F Morrey R A Adams R S Bryan

Fifty-three of 55 consecutive elbow replacements for post-traumatic arthritis were followed for a minimum of two years (mean 6.3, range 2 to 14.4). The patients presented difficult management problems, having undergone an average of two previous operations per joint; 22 joints had suffered prior complications; 18 had less than 50 degrees of flexion and six were flail. One of three versions of t...

Journal: :The Journal of arthroplasty 2005
George E Petsatodes John E Christoforides Pericles P Papadopoulos Anastasios G Christodoulou Dimitrios Karataglis John D Pournaras

A total of 233 Autophor 900-S fully porous coated stems were implanted in 220 patients with an average age of 47.5 years and an average follow-up of 13.5 years. The mean d' Aubigne-Postel score improved from 7.9 points preoperatively to 16.9 points postoperatively (P < .001). The overall result was excellent in 74.6%, good in 18.1%, fair in 5.8%, and poor in 1.5% of cases. One hip was revised f...

2013
Ralf H. Wittenberg Reinhard Steffen Henning Windhagen Petra Bücking Andreas Wilcke

Hip prosthesis stems with a short stem length and proximal fixation geometry support a bone-preserving and muscle-sparing implantation and should also allow for revision surgery with a standard hip stem. We present 250 prospectively documented clinical and radiological results from the Metha Short Hip Stem prosthesis (B. Braun-Aesculap, Tuttlingen, Germany) after an average follow-up of 4.9 yea...

2010
S. Pomianowski M. Urban D. Michalik B. Kordasiewicz D. Kowalski A. Podgorski B. Leszczynski

Fractures of the radial head constitute about 30% of all fractures around the elbow joint [1, 2]. Five to ten percent of all elbow dislocations are associated with peri-articular fractures, most commonly the radial head [3, 4, 5] In comminuted fractures of the radial head anatomic reduction and stable fixation are not always possible. In such cases the treatment is controversial – resection ver...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید