نتایج جستجو برای: potentiometric detection

تعداد نتایج: 568557  

2012
Mazhar Ali Abbasi Zafar Hussain Ibupoto Mushtaque Hussain Yaqoob Khan Azam Khan Omer Nur Magnus Willander

In this study honeycomb-like NiO nanostructures were grown on nickel foam by a simple hydrothermal growth method. The NiO nanostructures were characterized by field emission electron microscopy (FESEM), high resolution transmission electron microscopy (HRTEM) and X-ray diffraction (XRD) techniques. The characterized NiO nanostructures were uniform, dense and polycrystalline in the crystal phase...

2003
Harry B. Mark Y. L. Ma K. L. Petticrew H. Zimmer

The electrooxidation of catechols, catecholamines and NADH at conventional electrode materials is generally characterized by high degrees of irreversibility as well as strong adsorption and, hence, fouling by reactants and/or products of the reactions. On the contrary, the rates of the electron transfer are highly catalysed by the use of conducting polymer films, such as poly(3-methylthiophene)...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2004
Rakesh Kumar Mahajan Ravneet Kaur Inderpreet Kaur Vandana Sharma Manoj Kumar

A PVC membrane incorporating p-tert-butyl calix[4]crown with imine units as an ionophore was prepared and used in an ion-selective electrode for the determination of mercury(II) ions. An electrode based on this ionophore showed a good potentiometric response for mercury(II) ions over a wide concentration range of 5.0 x 10(-5) - 1.0 x 10(-1) M with a near-Nernstian slope of 27.3 mV per decade. T...

Journal: :journal of the iranian chemical research 0
zholt kormosh volyn national university, lutsk, ukraine iryna hunka volyn national university, lutsk, ukraine yaroslav bazel p.j. safaric university, slovakia

a simple, precise, rapid and low-cost potentiometric method for diclofenac determination in pharmaceuticals is proposed. a new diclofenac-sensitive electrode was constructed by incorporating the diclofenac ion pair complex with butyl rhodamine b into graphite matrix. the electrode exhibited a linear response over the concentration range of 1 × 10-4 – 5 × 10-2 mol l-1, a detection limit of 3.9×1...

Journal: :journal of physical & theoretical chemistry 2004
hossein aghaei masood giahi majjid arvand mehran aghaei

tin(ii)-ion-selective electrode consisting of dibenzo-18-crown-6 (db18c6) as an ionophore inpvc matrix was developed. the influences of membrane composition, selectivity, response time,reversibility and temperature on the electrode performance were investigated. the electrodeshowed a near nernstian response for sn2+ ions over a concentration range from 1.0× 10-6 – 1.0× 10-2 m with a slope of 27...

Journal: :journal of physical & theoretical chemistry 2007
m. aghaie m. h. fekri m. giahi e. baghdar s. farhadi

in order to study the cu(ii) ion selective electrode, an optimized membrane was prepared by mixing of 30 mg of pvc powdered, 5 mg of considered ionophore, 60 mg of plasticizer and 5 mg of additive. the sensor showed a near nernstian response for cu(ii) ions over a concentration range from 1.0×0-6 –1.0×0-2 m with a slope of 28.90.5 mv per concentration decade with a working ph range of 3.5-6.3. ...

Journal: :journal of physical & theoretical chemistry 2015
m. aghaie k. zare m. giahi

in this work, a novel zr02+ pvc-based membrane sensor based on 4,7,13,16,21,24-hexa oxa-1,10- diazabicyclo[8,8,8]- hexa cosane (hodbhc) as a new ionophore is presented. the sensor displays a linear dynamic rangebetween 1.0x 10-1 and 1.0x10 6 m, with a near nernstian slope of 29.9 ± 0.4 mv per decade in an acidic solution(ph=1). the limit of detection is 8.0 x 1 0 7 m. the electrodes possess adv...

Journal: :journal of physical & theoretical chemistry 2011
m. kia a. islamnezhad sh. shariati

in order to preparing strontium ion selective electrode 6-(4- nitropheny1)-2-pheny14, 4- dipropy1-3, 5-diaza-bicyclo [3, 1, 0] hex-2-ene (npdbh) was used as an ionophore. this electrode responds to sr (ii)ion with a sensitivity of 28.2 ± 0.5 mv/decade over the range 1.0 x 10-6 to 1.0 mat ph 3.0-10.0. thelimit of detection was 2.4 x 10-7 m. the influences of membrane composition, the ph of the t...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید