نتایج جستجو برای: plate fixation

تعداد نتایج: 121886  

2009
Hosam Fawzy Nasser Alhodaib C David Mazer Alana Harrington David Latter Daniel Bonneau Lee Errett James Mahoney

BACKGROUND Sternal instability with mediastinitis is a very serious complication after median sternotomy. Biomechanical studies have suggested superiority of rigid plate fixation over wire cerclage for sternal fixation. This study tests the hypothesis that sternal closure stability can be improved by adding plate fixation in a human cadaver model. METHODS Midline sternotomy was performed in 1...

2017
Pengbo Chen Hua Lu Hao Shen Wei Wang Binbin Ni Jishizhan Chen

BACKGROUND Lateral column tibial plateau fracture fixation with a locking screw plate has higher mechanical stability than other fixation methods. The objectives of the present study were to introduce two newly designed locking anatomic plates for lateral tibial plateau fracture and to demonstrate their characteristics of the fixation complexes under the axial loads. METHODS Three different 3...

2014
GS Jaura J Sikdar S Singh

ABSTRACT This is a report of a study on the long term results of PHILOS plating and percutaneous K-wire fixation in a prospective series of proximal humerus fractures in elderly patients. We reviewed a total of 60 patients with proximal humerus fractures in 30 patients (Group 1), who were treated by open reduction and internal fixation with Proximal Humeral Internal Locking System (PHILOS) plat...

2014
Qing-Jiang Pang Xiao Yu Zong-Hui Guo

OBJECTIVE In the surgery of calcaneal fracture, whether the sustentaculum tali screw should always be placed is widely controversial. The aim of this study was to explore the necessity and function of the sustentaculum tali screw placement for the treatment of Sanders type II calcaneal fracture. METHODS The finite element analysis was used in this study. After the establishment of the finite ...

2013
Sylvia A Stegeman Hakan Nacak Koen HJ Huvenaars Theo Stijnen Pieta Krijnen Inger B Schipper

Open Access This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the source is credited. DOI 10.3109/17453674.2013.786637 Background and purpose Type-II distal clavicle fractures according to the Neer classification are generally operated because of the hi...

Journal: :Injury 2012
Raja Mohd Aizat Raja Izaham Mohammed Rafiq Abdul Kadir Abdul Halim Abdul Rashid Md Golam Hossain T Kamarul

The use of open wedge high tibial osteotomy (HTO) to correct varus deformity of the knee is well established. However, the stability of the various implants used in this procedure has not been previously demonstrated. In this study, the two most common types of plates were analysed (1) the Puddu plates that use the dynamic compression plate (DCP) concept, and (2) the Tomofix plate that uses the...

Journal: :The Journal of bone and joint surgery. British volume 1993
T W Wright G J Miller R A Vander Griend D Wheeler P C Dell

Nine patients with nonunited humeral shaft fractures were treated by open reduction and internal fixation with an intramedullary fibular bone graft and a compression plate. Fixation of the screws was enhanced by passing them through the fibula as well as the two humeral cortices (quadricortical fixation). Eight of the nine fractures united at an average of 3.5 months. Tests on cadaver bones sho...

2011

Supra-condylar humerus fractures with extension into shaft are difficult to treat and typically require open anatomical reduction and internal fixation. Here we describe our experience treating distal humerus fractures using a triceps splitting approach with bicolumnar locking plate fixation.

Journal: :Vision Research 2013
Hiroshi Ueda Kohske Takahashi Katsumi Watanabe

The saccadic "gap effect" refers to a phenomenon whereby saccadic reaction times (SRTs) are shortened by the removal of a visual fixation stimulus prior to target presentation. In the current study, we investigated whether the gap effect was influenced by retinal input of a fixation stimulus, as well as phenomenal permanence and/or expectation of the re-emergence of a fixation stimulus. In Expe...

2017
Chih-Kun Hsiao Yi-Jung Tsai Cheng-Yo Yen Cheng-Hung Lee Teng-Yao Yang Yuan-Kun Tu

BACKGROUND Proximal humeral fractures treated with locking plate can fail due to varus collapse, especially in osteoporotic bone with medial cortex comminution. The use of an intramedullary strut together with locking plate fixation may strengthen fixation and provide additional medial support to prevent the varus malalignment. This study biomechanically investigates the influence of an intrame...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید