نتایج جستجو برای: phantom ct mtf phantom autocad modulation

تعداد نتایج: 300098  

Journal: :Physics in medicine and biology 2005
Hengyong Yu Shiying Zhao Ge Wang

Recently, several exact cone-beam reconstruction algorithms, such as the generalized filtered-backprojection (FBP) and backprojection-filtration (BPF) methods, have been developed to solve the long object problem. Although the well-known 3D Shepp-Logan phantom (SLP) is often used to validate these algorithms, it is deficient due to the discontinuity of the SLP. In this paper, we first construct...

2016
David Goodenough Josh Levy Smari Kristinsson Jesper Fredriksson Hildur Olafsdottir Austin Healy

Increasingly, the advent of multislice CT scanners, volume CT scanners, and total body spiral acquisition modes has led to the use of Multi Planar Reconstruction and 3D datasets. In considering 3D resolution properties of a CT system it is important to note that both the in-plane (x,y) and z-axis (slice thickness) influence the visual-ization and detection of objects within the scanned volume. ...

2001
Cheng Yu Zbigniew Petrovich Michael L. J. Apuzzo Gary Luxton

A special acrylic phantom designed for both magnetic resonance imaging (MRI) and computed tomography (CT) was used to assess the geometric accuracy of MRI-based stereotactic localization with the Leksell stereotactic head frame and localizer system. The acrylic phantom was constructed in the shape of a cube, 164 mm in each dimension, with three perpendicular arrays of solid acrylic rods, 5 mm i...

2016
Jonathan I. Gear Craig Cummings Allison J. Craig Antigoni Divoli Clive D. C. Long Michael Tapner Glenn D. Flux

BACKGROUND The use of selective internal radiation therapy (SIRT) is rapidly increasing, and the need for quantification and dosimetry is becoming more widespread to facilitate treatment planning and verification. The aim of this project was to develop an anthropomorphic phantom that can be used as a validation tool for post-SIRT imaging and its application to dosimetry. METHOD The phantom de...

2017
Jae Won Park Se An Oh Ji Woon Yea Min Kyu Kang

A three-dimensional (3D)-printed customized bolus (3D bolus) can be used for radiotherapy application to irregular surfaces. However, bolus fabrication based on computed tomography (CT) scans is complicated and also delivers unwanted irradiation. Consequently, we fabricated a bolus using a 3D scanner and evaluated its efficacy. The head of an Alderson Rando phantom was scanned with a 3D scanner...

2012
Yuji Yaegashi Kunihiko Tateoka Takuya Nakazawa Kazunori Fujimoto Katsumi Shima Junji Suzuki Akihiro Nakata Yuichi Saito Tadanori Abe Koichi Sakata Masato Hareyama

We aimed to optimize internal margin (IM) determination for respiratory-gated radiotherapy using end-expiratory phase assessments using a motion phantom. Four-dimensional computed tomography (4D CT) data were acquired using a GE LightSpeed RT CT scanner, a respiratory-gating system, and a motion phantom designed to move sinusoidally. To analyze the accuracy of 4D CT temporal resolution, a 25.4 ...

Journal: :Applied sciences 2022

(1) Background: New generation of PET-CT scanners allows performing volumetric dosimetry based on 90Y-activity distribution. The aim this study was to perform an up-to-date evaluation the optimal 90Y-PET-CT reconstruction parameters for a Siemens Biograph mCT scanner. (2) Methods: A cylindrical uniform phantom (P1), IEC NEMA Body-phantom (P2) and Torso-phantom (P3) filled with 90Y were acquired...

2017
Daniëlle Koopman Maureen Groot Koerkamp Pieter L Jager Hester Arkies Siert Knollema Cornelis H Slump Pedro G Sanches Jorn A van Dalen

BACKGROUND Our aim was to evaluate if a recently introduced TOF PET system with digital photon counting technology (Philips Healthcare), potentially providing an improved image quality over analogue systems, can fulfil EANM research Ltd (EARL) accreditation specifications for tumour imaging with FDG-PET/CT. FINDINGS We have performed a phantom study on a digital TOF PET system using a NEMA NU...

Journal: :Diagnostics 2021

We evaluated the accuracy of coronary artery calcium (CAC) scoring on a dual-source photon-counting detector CT (PCD-CT). An anthropomorphic chest phantom underwent ECG-gated sequential scanning PCD-CT at 120 kV with four radiation dose levels (CTDIvol, 2.0–8.6 mGy). Polychromatic images (T3D) and virtual monoenergetic (VMI), from 60 to 75 keV without quantum iterative reconstruction (no QIR) Q...

2011
Ruben Pauwels Harry Stamatakis Giorgos Manousaridis Adrian Walker Koen Michielsen Hilde Bosmans Ria Bogaerts Reinhilde Jacobs Keith Horner Kostas Tsiklakis

Cone-beam CT (CBCT) has shown to be a useful imaging modality for various dentomaxillofacial applications. However, optimization and quality control of dental CBCT devices is hampered due to the lack of an appropriate tool for image quality assessment. To investigate the application of different image quality parameters for CBCT, a prototype polymethyl methacrylate (PMMA) cylindrical phantom wi...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید