2009
S. Nagarajaiah Takuji Kobori

Tuned mass dampers (TMD), active mass dampers (AMD) and hybrid mass dampers (HMD) have been widely applied for vibration control of tall buildings and bridges in the past decade. Recently, the author and his coworkers have developed semiactive or smart tuned mass dampers (STMD) using semiactive variable stiffness systems. STMD’s are superior than TMD’s in reducing the response of the primary st...

Journal: :MATEC web of conferences 2021

Mathematical modeling and experimental research represented in this paper is aimed at dynamic force analysis of circuit cards order to eliminate or reduce stress deflection an acceptable level provide strength reliability design card assemblies subjected vibration. In conditions when viscous friction forces are negligible dampers, such as liquid cannot be used reduction oscillation amplitude cr...

2010
Arash Bahar Francesc Pozo Leonardo Acho José Rodellar Alex Barbat

Magnetorheological (MR) dampers have received special attention as semi-active devices for mitigation of structural vibrations. Because of the inherent nonlinearity of these devices, it is difficult to obtain a reasonable mathematical inverse model. This paper is concerned with two related concepts. On one hand, it presents a new inverse model of MR dampers based on the normalized Bouc–Wen mode...

Journal: :Anesthesiology 2004
Daniel P Vezina Claude A Trépanier Martin R Lessard Marie Gourdeau Claude Tremblay Robert Guidoin

BACKGROUND The use of breathing filters (BFs) has been recommended to protect the anesthesia apparatus in proven or suspected cases of tuberculosis. Some investigators have also suggested the use of BF to alleviate the need to change anesthesia breathing circuits after each case. This study evaluated the filtration efficacy of three different BFs to prevent mycobacterial contamination of breath...

2002
E. A. Johnson

Cables, such as are used in cable-stayed bridges, suspension bridges, guy wires, transmission lines, and flexible space structures, are prone to vibration due to their low inherent damping characteristics. The mitigation of cable vibration is necessary to minimize negative impact. Transversely-attached passive viscous dampers have been implemented on some cables to dampen vibration. However, it...

1999
Erik A. Johnson Greg A. Baker Yozo Fujino

A BSTRACT : Stay cables, such as are used in cable-stayed bridges, are prone to vibration due to their low inherent damping characteristics. Transversely-attached passive viscous dampers have been implemented in many bridges to dampen such vibration. Several studies have investigated optimal passive linear viscous dampers; however, even the optimal passive device can only add a small amount of ...

2004
J. S. Hwang

The current design formulas such as those provided by FEMA273/274 for building structures with supplemental viscous dampers were derived based on the shear building assumption. However, for medium-rise to high-rise buildings that deform in a combined form of shear and bending when subjected to seismic loading, the design using existing formulas may result into an actual damping ratio much lower...

Journal: :Finnisch-Ugrische Forschungen 2014

2002
E. A. Johnson R. E. Christenson

Cables, such as are used in cable-stayed bridges, suspension bridges, guy wires, transmission lines, and flexible space structures, are prone to vibration due to their low inherent damping characteristics. The mitigation of cable vibration is necessary to minimize negative impact. Transversely-attached passive viscous dampers have been implemented on some cables to dampen vibration. However, it...