نتایج جستجو برای: pagata gel dosimeter

تعداد نتایج: 106920  

Journal: :Chest 2005
Nathan D Allen Beth E Davis Thomas S Hurst Donald W Cockcroft

BACKGROUND Two bronchoprovocation methods are widely used. Compared to the tidal breathing method, the dosimeter method delivers approximately half the dose and involves five deep inhalations. Both the lower dose and the bronchoprotective deep inhalations contribute to the lesser airway response of the dosimeter. OBJECTIVE To determine the relative role of dose and deep inspiration in the dif...

Journal: :Physics in medicine and biology 2015
Y De Deene P S Skyt R Hil J T Booth

Three dimensional radiation dosimetry has received growing interest with the implementation of highly conformal radiotherapy treatments. The radiotherapy community faces new challenges with the commissioning of image guided and image gated radiotherapy treatments (IGRT) and deformable image registration software.A new three dimensional anthropomorphically shaped flexible dosimeter, further call...

2010
T. Allahverdi Pourfallah M. Allahverdi N. Riyahi Alam M. R. Ay M. H. Zahmatkesh

*Corresponding author: Dr. Tayyeb Allahverdi Pourfallah, Department of Medical Physics and Biomedical Engineering, Tehran University of Medical Sciences, Tehran, Iran. Fax: +98 21 88973653 E-mail: [email protected] Background: Polymer gel dosimetry is still the only dosimetry method for direct measuring of threedimensional dose distributions. MRI Polymer gel dosimeters are tissue equi...

2012
Tayeb Allahverdi Pourfallah Mahmoud Allahverdi Mohammad Hasan Zahmatkesh

Introduction Polymer gel dosimeters offer a practical solution to 3D dose verification for conventional radiotherapy as well as intensity-modulated and stereotactic radiotherapy. In this study, EGSnrc calculated and PAGAT polymer gel dosimeter measured dose profiles from single shot irradiation with 18 mm collimator of Gamma Knife in homogeneous and inhomogeneous phantoms were compared with eac...

2013
M Mahdavi M KhademAbolfazli S-R-M Mahdavi Gh Ataei

BACKGROUND Radiation-sensitive polymer gels are among the most promising three-dimensional dose verification tools and tissue-like phantom developed to date. OBJECTIVE The aim of this study is an investigating of percentage depth dose enhancement within the gel medium with used of conformal distribution gold nanoparticle as contrast agents by high atomic number material. METHODS In this wor...

2006
Panagiotis Sandilos Elias Tatsis Lampros Vlachos Constantinos Dardoufas Pantelis Karaiskos Evangelos Georgiou Panagiotis Baras Panagiotis Kipouros Michael Torrens Angelos Angelopoulos

The polymer gel-Magnetic Resonance Imaging (MRI) dosimetry technique was employed to evaluate the mechanical and dose delivery accuracy in Leksell gamma knife stereotactic radiosurgery for the treatment of multiple targets. Two different polymer gel dosimeter formulations that have been reported in the literature were prepared in-house. A plan for the treatment of four brain metastases (targets...

2017
Yi Du Gongyi Yu Xincheng Xiang A Asena S T Smith T Kairn S B Crowe

This study demonstrates the degradation in image quality, and subsequent dose evaluation inaccuracies, that are encountered when an optical-CT system reconstructs an image slice of a gel dosimeter containing an opaque implant, and evaluates the feasibility of a simple correction method to improve the accuracy of radiotherapy dose distribution measurements under these circumstances. MATLAB was u...

اربابی, عظیم, بلوری, بهرام, ندایی, حسن, قهرمان اصل, روح اله,

  Background & Aim: Nowadays, radiosensitive polymer gels are used as a reliable dosimetry tool for verification of 3D dose distributions. Polymer gel dosimeters consist of an aqueous mixture of monomers and a gelling agent, which after irradiation, 3D dose distribution is acquired by using imaging techniques. The aim of this study is to evaluate the application and capability of normoxic polym...

A. Takavar, A. Vaezzadeh, H.A. Nedaie, M. Keshtkar, M. Naderi, M.H. Zahmatkesh,

Background: Some tissues in human body are radiobiologically different from water and these inhomogeneity must be considered in dose calculation in order to achieve an accurate dose delivery. Dose verification in complex radiation therapy techniques, such as intensity‐modulated radiation therapy (IMRT) calls for volumetric, tissue equivalent and energy independent dosimeter. The purpose of this...

Mahmoud Allahverdi Mohammad Hasan Zahmatkesh Tayeb Allahverdi Pourfallah,

Introduction Polymer gel dosimeters offer a practical solution to 3D dose verification for conventional radiotherapy as well as intensity-modulated and stereotactic radiotherapy. In this study, EGSnrc calculated and PAGAT polymer gel dosimeter measured dose profiles from single shot irradiation with 18 mm collimator of Gamma Knife in homogeneous and inhomogeneous phantoms were compared with eac...